Symptom: Sprayer does not run, stops running, or will
not shut off.
1. Perform
2. Set power switch OFF for 30 seconds and then ON
again (this ensures sprayer is in normal run mode).
3. Turn pressure control knob clockwise 1/2 turn.
4. Remove control box cover to view control board
status light. To determine which code refer to the
control board status light. Turn the ON/OFF switch
OFF, remove the control cover then turn power back
ON. Observe the status light. Blinking LED total
count equals the error code (for example: two blinks
equals CODE 02).
Keep clear of electrical and moving parts during
troubleshooting procedures. To avoid electrical shock
hazards when covers are removed for
troubleshooting, wait five minutes after unplugging
power cord for stored electricity to dissipate.
D20
D20
Control Board Status Light
TYPE OF PROBLEM
WHAT TO CHECK
HOW TO CHECK
Sprayer does not run at all
See flow chart, page 68.
Control board status light never
lights
Sprayer does not run at all
Check transducer or transducer
connections
1.
Make sure there is no pressure in the system (see
fluid path for clogs, such as clogged filter.
2.
Use airless paint spray hose with no metal braid 3/8
x 20’ minimum. Smaller hose or metal braid hose
may result in high-pressure spikes.
3.
Set sprayer to OFF and disconnect power to
sprayer.
4.
Check transducer and connections to control board.
5.
Disconnect transducer from control board socket.
Check that transducer and control board contacts
are clean and secure.
6.
Reconnect transducer to control board socket.
Connect power, set sprayer ON and control knob
1/2 turn clockwise. If sprayer does not run properly,
set sprayer to OFF and go to next step.
7.
Install new transducer. Connect power, set sprayer
ON and control knob 1/2 turn clockwise. Replace
control board if sprayer does not run properly.
Control board status light blinks
2 times repeatedly
Содержание LineLazer ES 1000
Страница 38: ...ES2000 HP Auto Series 38 3A4603F Operation Repair Parts ES2000 HP Auto Series ...
Страница 91: ...Wiring Diagram 230V ES 1000 3A4603F Operation Repair Parts 91 Wiring Diagram 230V ES 1000 ...
Страница 109: ...Wiring Diagram 120V ES 2000 3A4603F Operation Repair Parts 109 Wiring Diagram 120V ES 2000 ...
Страница 110: ...Control Board Wiring Diagram 110 3A4603F Operation Repair Parts Control Board Wiring Diagram 110 120V ES2000 ...
Страница 112: ...Wiring Diagram 230V ES 2000 112 3A4603F Operation Repair Parts Wiring Diagram 230V ES 2000 ...