LineLazer V LiveLook Display
32
3A4603F Operation, Repair, Parts
3. Press
to select Setup/Information.
4. Press for
Calibration.
Set TRAVEL DIST to 25 ft
(7.6m) or longer. Longer distances ensure better
accuracy, depending on conditions.
\
5. Align part of the unit with 1 foot (30.5cm) on steel
tape.
6. Push
to start calibration.
7. Move striper forward. Keep unit aligned with steel
tape.
8. Stop when chosen part of unit aligns with 26-ft (8m),
or distance entered, on steel tape (25-ft./ 7.6m dis-
tance).
9. Push
to complete calibration.
•
Calibration is not complete when the exclamation
symbol
is displayed.
•
Calibration is finished when the check mark symbol
is displayed.
10. Calibration is now complete.
Measure Mode (ES2000 Standard Series)
34, and verify accuracy by measuring the tape.
ti27827a
ti27830a
1
FT
2
FT
3
FT
4
FT
5
FT
6
F
ti27831a
ti27826a
26
FT
27
FT
28
FT
29
FT
30
FT
31
F
25
FT
ti27832a
ti27941a