![Graco LineLazer ES 1000 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/graco/linelazer-es-1000/linelazer-es-1000_installation-repair-parts_2250938016.webp)
Pressure Relief Procedure
16
3A4603F Operation, Repair, Parts
Pressure Relief Procedure
1. Perform
Grounding Procedure
if using flammable
materials.
2. Turn ON/OFF Switch to
OFF
.
3. Turn pressure control to lowest setting. Trigger all
guns to relieve pressure.
4. Engage all gun trigger locks. Turn prime valve
down.
v
5. If you suspect the spray tip or hose is clogged or
that pressure has not been fully relieved:
a. VERY SLOWLY loosen the tip guard retaining
nut or the hose end coupling to relieve pressure
gradually.
b. Loosen the nut or coupling completely.
c. Clear the obstruction in the hose or tip.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing fluid
and moving parts, follow the
Pressure Relief
Procedure
when you stop dispensing and before
cleaning, checking, or servicing the equipment.
ti30322a
ti30323a
ti27608a
Содержание LineLazer ES 1000
Страница 38: ...ES2000 HP Auto Series 38 3A4603F Operation Repair Parts ES2000 HP Auto Series ...
Страница 91: ...Wiring Diagram 230V ES 1000 3A4603F Operation Repair Parts 91 Wiring Diagram 230V ES 1000 ...
Страница 109: ...Wiring Diagram 120V ES 2000 3A4603F Operation Repair Parts 109 Wiring Diagram 120V ES 2000 ...
Страница 110: ...Control Board Wiring Diagram 110 3A4603F Operation Repair Parts Control Board Wiring Diagram 110 120V ES2000 ...
Страница 112: ...Wiring Diagram 230V ES 2000 112 3A4603F Operation Repair Parts Wiring Diagram 230V ES 2000 ...