Purge
Purge
Purge Screens
Screens
Screens 1–5
1–5
1–5
Use the Purge screens to configure up to 5 purge
profiles. Customize each purge profile to best suit
different fluids.
Purge:
Purge:
Purge: Assign a number to the purge profile.
The purge profile number can be used:
• In the Home screen when in Purge mode. See
• In the Presets screen to associate a purge profile
with a paint color. See
Timeout:
Timeout:
Timeout: The number of seconds that the system
waits for action before it indicates that there is a
problem completing the purge profile. The timeout
should be set long enough to complete the refill
cycles. Enter 0 to disable the timeout.
Fluid:
Fluid:
Fluid: Set the fluid pressure for the fluid to exit the
system during this purge profile.
The remaining settings define the actions in the purge sequence:
1
Dump
Dump
Dump
Enable:
Enable:
Enable:
Check this box if the dump valve is connected to a hose that empties into a waste
container. If the dump valve is not connected to a hose, be sure to clear this box, or the
remaining contents from the pump will spill out of the system.
2
Air
Air
Air Push:
Push:
Push:
After the pump is empty, the number of seconds that air pushes through the system.
Enter 0 to skip the air push.
3
Flush
Flush
Flush Push:
Push:
Push:
The number of seconds that flush fluid pushes through the system. Enter 0 to skip
the flush push.
4
Refill
Refill
Refill Cycles:
Cycles:
Cycles:
The number of times to empty and refill the pump. Enter 0 to skip the refill cycles.
5
Flush
Flush
Flush Dump:
Dump:
Dump:
Enter the number of seconds to open both the flush material valve and the dump valve.
This cleans the dump valve line.
6
Chop:
Chop:
Chop:
Check this box to add a flush period of alternating fluid and air to the purge sequence.
• Air
Air
Air Chop:
Chop:
Chop: The number of seconds for the air interval.
• Flush
Flush
Flush Chop:
Chop:
Chop: The number of seconds for the fluid interval.
• Total
Total
Total Chop:
Chop:
Chop: The total number of seconds that the air and fluid will alternate through
the system.
7
Final
Final
Final Push:
Push:
Push:
Select the last action of the purge sequence:
• None:
None:
None: Perform no final action. The purge is complete after the Refill Cycles or the
Chop has completed.
• Air:
Air:
Air: Push air through the system for a number of seconds.
• Flush:
Flush:
Flush: Push flush fluid the system for a number of seconds.
3A8493A