Control Interface Setup and Maintenance
Upload
Upload
Upload System
System
System Configuration
Configuration
Configuration
Use this procedure to install a system configuration
file and/or a custom language file.
1.
If necessary, follow
, to
automatically generate the proper folder structure
on the USB flash drive.
2.
Insert the USB flash drive into the USB port of
computer.
3.
The USB flash drive window automatically opens.
If it does not, open the USB flash drive from
within Windows Explorer.
4.
Open the Graco folder.
5.
Open the system folder. If working with more
than one system, there is more than one folder
within the Graco folder. Each folder is labeled
with the corresponding serial number of the
control interface. (The serial number is on the
back of the control interface.)
6.
If installing the system configuration settings file,
place the SETTINGS.TXT file into the UPLOAD
folder.
7.
If installing the custom language file, place the
DISPTEXT.TXT file into the UPLOAD folder.
8.
Remove the USB flash drive from the computer.
9.
Install the USB flash drive into the USB port on
the control interface.
10. The menu bar and USB indicator lights indicate
that the USB is downloading files. Wait for USB
activity to complete.
11. Remove the USB flash drive from the USB port.
Note:
Note:
Note: If the custom language file was installed, users
can select a different language from the Language
drop-down menu in the Advanced Setup Screen 1.
See
Clean
Clean
Clean the
the
the Screen
Screen
Screen Surface
Surface
Surface
Use any alcohol-based household cleaner, such as
glass cleaner, to clean the control interface.
Update
Update
Update the
the
the System
System
System Software
Software
Software
A new HydroShield system includes a control
interface that is pre-programmed to operate the
HydroShield system. If the control interface is
replaced, a Graco black software update token
(17Z578) is included, which contains the latest
software. Use the token to program the replacement
control interface, as described in 3A1244. See
.
The token uses Token In-System Programming,
which provides the capability to transfer software
updates from a USB drive to the token. With this
feature, you can obtain the software updates online,
download them to a USB drive, and transfer them
directly to the token instead of waiting for a new
software update token to be shipped.
If you already have a Graco black software update
token, you can use it to update the HydroShield
system software.
Note
This process is for Graco black tokens only,
not Graco blue tokens.
Note
All update files must have either file
extension *.GTI (software update files) or
*.GMI (gateway map files). A maximum of 14
files can be present in the \Graco\Software\
folder.
To update the software on the isolation system:
• Download the latest software version for the
system from the Graco website. Follow the steps
in
Obtain Software Updates, page 41
• Transfer the software to the control
interface.
Follow the steps in
Transfer Software from USB to System, page 42
.
Obtain
Obtain
Obtain Software
Software
Software Updates
Updates
Updates
Use a computer with internet access to obtain
software updates for the system.
1.
Insert a USB drive into a USB port on your
computer.
2.
Open an internet browser and go to
help.graco.com.
3.
Navigate to the desired software update.
3A8493A