Control Interface Setup and Maintenance
Control
Control
Control Interface
Interface
Interface Setup
Setup
Setup and
and
and Maintenance
Maintenance
Maintenance
Enable
Enable
Enable USB
USB
USB Data
Data
Data
If the system is configured with USB capability,
be sure to check (enable) the box for Enable USB
Downloads/Uploads on
.
All files downloaded from the USB are put in a
DOWNLOAD folder on the drive.
For example: “E:\GRACO\12345678\DOWNLOAD\”
The 8-digit numeric folder name matches the 8-digit
serial number on the control interface. When
downloading from multiple controllers, there is one
sub-folder in the GRACO folder for each control
interface.
USB
USB
USB Logs
Logs
Logs
During operation, the control interface stores system
and performance related information to memory in
the form of log files. It maintains two types of log
files: an event log and system logs. To retrieve log
files, see
.
Event
Event
Event Log
Log
Log
The event log file name is 1-EVENT.CSV and is
stored in the DOWNLOAD folder.
The event log maintains a record of the last 1,000
events. Each event record in the log file contains the
date and time the event occurred, the event type,
event code, and event description.
System
System
System Log
Log
Log
The system log file name is 2-SYSTEM.CSV and is
stored in the DOWNLOAD folder.
The system log maintains a record of all control
interface modules connected to the system. Each
event record in the log file contains the date, time,
software part number, and software version.
System
System
System Configuration
Configuration
Configuration Settings
Settings
Settings File
File
File
The system configuration settings file name is
SETTINGS.TXT and is stored in the DOWNLOAD
folder.
A system configuration settings file automatically
downloads each time a USB flash drive is inserted.
Use this file to back up system settings for future
recovery or to easily replicate settings across multiple
systems. For instructions on how to use this file,
see
Upload System Configuration, page 41
.
For the location of the USB port on the control
module, see
Connect the CAN Cables, page 23
Retrieve the SETTINGS.TXT file after all system
settings are set as desired. Store the file for future
use as a backup in case the settings are changed
and need to be quickly changed back to the desired
setup.
Note
• System settings may not be compatible
between different versions of the software.
• Do not modify the contents of this file.
Custom
Custom
Custom Language
Language
Language File
File
File
The custom language file name is DISPTEXT.TXT
and is stored in the DOWNLOAD folder.
A custom language file automatically downloads each
time a USB flash drive is inserted. If desired, use this
file to create a user-defined set of custom language
strings to be displayed within the control interface.
The control interface is able to display the following
Unicode characters. For characters outside of this
set, the system displays the Unicode replacement
character, which appears as a white question mark
inside of a black diamond.
• U+0020 - U+007E (Basic Latin)
• U+00A1 - U+00FF (Latin-1 Supplement)
• U+0100 - U+017F (Latin Extended-A)
• U+0386 - U+03CE (Greek)
• U+0400 - U+045F (Cyrillic)
3A8493A
39
Содержание HydroShield WABL00