Operation
Operation
Operation
Operation
Operation
Operation Overview
Overview
Overview
1.
Plug in the system. The system
powers up and enters Off mode. See
Connect the Power Supply, page 24
2.
Verify that the fluid supply and air supply are
connected. Press the Power button
. The
system enters Standby mode.
3.
Prime the system. Use the control interface
to change the mode to Prime mode. See
. Trigger the gun until
your material dispenses from the gun.
4.
Use the control interface to set the fluid
pressure if using a system with a regulator. See
.
5.
Use the control interface to change the mode
to Spray mode. The system begins to fill. See
.
6.
Request electrostatics and begin to spray.
Note:
Note:
Note:The system automatically refills when the
gun trigger is released, the electrostatic request
is disabled, and the fluid level is below the Start
Fill setting.
For information about the Start Fill setting, see
Pump Screen 1: Pump Volume, page 54
.
Fluid
Fluid
Fluid Voltage
Voltage
Voltage Discharge
Discharge
Discharge and
and
and
Grounding
Grounding
Grounding Procedure
Procedure
Procedure
The fluid supply is charged with high voltage until
the voltage is discharged. Contact with the charged
components of the voltage isolation system or
spray gun electrode will cause an electric shock.
To avoid an electric shock, do not alter or bypass
the door switch interlock and follow the Fluid
Fluid
Fluid
Voltage
Voltage
Voltage Discharge
Discharge
Discharge and
and
and Grounding
Grounding
Grounding Procedure:
Procedure:
Procedure:
• Whenever you are instructed to discharge the
voltage
• Before cleaning, flushing, or servicing the system
equipment
• Before approaching the front of the gun
• Before opening the isolation cabinet
1.
Release the gun trigger and turn off electrostatics.
2.
Disable the electrostatic request signal to turn
off electrostatics.
3.
After the ground rod delay time elapses, the
ground rod (N) inside the isolation cabinet lowers
and discharges the system. Look at the main
system run screen on the control interface to
verify that the system is discharged:
a.
Check that the Ground Rod status indicator
shows the ground symbol
. See
.
b.
Check that the Voltage Level reading
on the control interface reads 0 kV. See
.
c.
Touch the gun electrode to a grounded rod.
Note:
Note:
Note: If maintenance or service is required inside
the isolation cabinet continue with the following
steps:
4.
Press the Stop button
on the control
interface to change to Off mode.
5.
Wait one minute before entering the isolation
cabinet. Use a flat blade screwdriver to open the
cabinet.
6.
Use the hand-held grounded rod (R) to dissipate
any static discharge in the cabinet before
touching any components. Pick up the grounded
rod (R) and use it to touch all major components
inside the cabinet. For example, use it to touch
the isolation fluid pump (K), the fluid pressure
regulator (L), and the isolation valve (G) before
touching any of the system components with
your hands.
3A8493A
29