Events
Events
Events Screen
Screen
Screen
Use the Events screen to view the last 99 status
messages generated by the isolation system. Click
the up and down arrows on the right of the screen to
scroll through the messages.
Each message line includes the date, the time, and
the status code. See
Status
Status
Status Screens
Screens
Screens
The Status screens display a summary of the input
signals that are monitored by the system and the
solenoids that drive system activity. The screens are
for information and troubleshooting purposes.
Status
Status
Status Screen
Screen
Screen 1
1
1
The Status screens display a summary of the input
signals that are monitored by the system and the
solenoids that drive system activity. The Status
screens are for information and troubleshooting
purposes.
Inputs
Inputs
Inputs
Inputs are signals that the system acts on. When the
status circle next to the input appears yellow, the
sensor is activated.
• System
System
System Stop:
Stop:
Stop: Air:
Air:
Air: The external pneumatic input
that tells the system to stop. The system stop
pneumatic input is available only when the optional
System Stop Pneumatic Input Kit 26B414 is
installed. To install, see
Stop Pneumatic Input Kit, page 25
• System
System
System Stop:
Stop:
Stop: Digital:
Digital:
Digital: The external electrical input
that tells the system to stop. The system stop
digital input is available only when the optional
Optocoupler Kit 24Z226 is installed. To install, see
Install the Optional System Status Output, page 26
.
• Inlet
Inlet
Inlet Air:
Air:
Air: Indicates the minimum required air
pressure 70 psi (0.5 MPa, 4.8 bar) is detected.
• Shuttle
Shuttle
Shuttle Top:
Top:
Top: The sensor that indicates that the
isolation valve is in the top position.
• Shuttle
Shuttle
Shuttle Bottom:
Bottom:
Bottom: The sensor that indicates that the
isolation valve is in the bottom position.
• Gun
Gun
Gun Flush
Flush
Flush Box:
Box:
Box: The sensor that indicates that the
gun flush box is closed. Not used on automatic
systems.
• Fluid
Fluid
Fluid Trigger:
Trigger:
Trigger: The air flow switch that indicates
that the gun is triggered. Not used on automatic
systems.
Solenoids
Solenoids
Solenoids
Electrical to pneumatic actuators that drive system
activity.
• Shuttle
Shuttle
Shuttle Down:
Down:
Down: Drives the isolation valve down and
open for filling.
• Shuttle
Shuttle
Shuttle Up:
Up:
Up: Drives the isolation valve up and
closed for isolating the charged fluid.
• Shuttle
Shuttle
Shuttle Eject:
Eject:
Eject: From the down position, ejects the
isolation valve up from the seat.
• Shuttle
Shuttle
Shuttle Fluid
Fluid
Fluid In:
In:
In: Opens the fluid valve near the
system fluid inlet.
• Pump
Pump
Pump Fluid
Fluid
Fluid In:
In:
In: Opens the fluid valve near the
isolation fluid pump fluid inlet when it is present.
This fluid valve is not present in standard systems.
Purchase a conversion kit to replace a spring
check valve with a pneumatically activated fluid
inlet valve.
• Pump
Pump
Pump Pressure:
Pressure:
Pressure: Activates the air pressure to the
isolation fluid pump.
• Ground
Ground
Ground Rod:
Rod:
Rod: Activates (raises) the ground rod to
allow the system to build a charge.
• Gun
Gun
Gun Flush
Flush
Flush Box:
Box:
Box: Activates the gun trigger in the
gun flush box. Not used on automatic systems.
• System
System
System Status:
Status:
Status: Indicates to the system that it is
okay to spray.
50