Run
Run
Run Menus
Menus
Menus
Home
Home
Home Screen
Screen
Screen
The Home screen is the primary screen that the
operator uses while painting. When the system is
powered, it enters Off mode.
The operator must first select Standby mode for
painting. The available settings vary depending on
whether color change is enabled on the system.
After Standby is selected, the operator can select the
Prime, Purge, or Spray buttons.
Table
Table
Table 1
1
1 Key
Key
Key to
to
to System
System
System Modes
Modes
Modes
Soft
Soft
Soft Key
Key
Key
Function
Function
Function
Standby
Standby
Standby
Press to put the system into Standby
mode. Standby mode is used to prepare
the system for operation or for a break
in operation, such as a shift change. All
fluid valves are closed and all air valves
are off. The isolation valve (G) is in the
down (bottom) position.
In Standby mode, the system verifies
that there is inlet air supply and that
the minimum required 70 psi (0.5 MPa,
4.8 bar) air pressure is supplied to the
system.
Prime
Prime
Prime
Press to enter Prime mode. Prime mode
is used to load the system with new
material. The volume in the isolation
fluid pump (K) is minimized. The system
stays grounded.
Soft
Soft
Soft Key
Key
Key
Function
Function
Function
Purge
Purge
Purge
Press to enter Purge mode. Purge
mode is used for flushing the system
or changing colors. The isolation fluid
pump (K) fills and dispenses, but the
system stays grounded.
In Purge mode with color change
enabled, the buttons that are available
vary depending on whether the operator
is in Preset 0 or is using a purge profile:
• Preset 0 presents buttons for the
operator to perform a manual purge.
• Purge profiles present a play button
for the purge profile to automatically
perform a preconfigured purge
sequence.
See
Home Screen in Purge Mode, page 49
.
Spray
Spray
Spray
Press to enter mode. Spray mode
is used for painting. As soon as the
system enters Spray mode, the isolation
fluid pump (K) begins to fill.
When the gun is triggered to spray, the
isolation valve (G) raises and the pump
is pressurized. When the ES request
input is active the ground rod (N) raises
to allow the system to build voltage.
When both the gun trigger is released
and the ES request input is disabled the
isolation valve (G) and the ground rod
(N) lower. The system discharges and
the pump begins to refill.
To enter Spray mode, you must first be
in either Prime or Standby mode. You
cannot enter Spray mode directly from
Purge mode.
In Spray mode, the menu bar displays
the following:
• Fill when the pump is filling.
• Ready when the pump is full and the
system is waiting for a gun trigger.
• Dispense when the gun is triggered
for spraying and/or the ES request
input is active.
3A8493A
45
Содержание HydroShield WABL00
Страница 118: ...Parts Notes Notes Notes 118 3A8493A...