Appendix E - System Events
3A2175Z
97
Appendix E - System Events
Event Code and
String
Triggers
ECC1-R: Cavitation
Errors On
The cavitation error generation logic is
turned ON (default and recommended
state for production use).
ECC0-R: Cavitation
Errors Off
The user has turned OFF the
Cavitation Error Generation logic (not
recommended for production use).
This event also generates if cavitation
errors are off when the product
powers up. An error will not generate if
an HFR pump does not completely fill,
and the material ratio may be
incorrect.
ECD0-R: Mixer Motor
Disabled for Dispense
User has activated function (Pressed
“
” key) which may have negative
effects on future dispenses.
ECD1-R: Mixer Motor
Enabled for Dispense
User has re-enabled the mixer motor
for dispensing.
ECF0-R: Mixer Air
OFF for Dispense
User has activated function (Pressed
“
” key) which may have negative
effects on future dispenses.
ECF1-R: Mixer Air
Enabled for Dispense
User has re-enabled Air Nucleation for
dispensing.
ECGX: Dispense
Recipe Altered by
PLC
The rate (flow or pressure) or amount
has been altered by the controlling
CGM/PLC interface when the system
was in shot mode.
REL00: System Pow
-
ered On
The System was powered on.
REM00: System
Powered Off
The System was powered off.
REB00: Stop Button
Pressed
The Red stop button was pressed on
the Advanced Display Module.
RECH0: Learn Mode
Executed
A learn mode calibration was success
-
fully completed.
RENN0: Automatic
Cal. Performed
The system was successfully charac
-
terized with the Automatic calibration.
RECA1: Red Material
SG Modified
The Red materials specific gravity was
modified.
RECB2: Blue Mate
-
rial SG Modified
The Blue materials specific gravity
was modified.
RENC1: Cal. Point 1
Weight Entered
A value for the first point in the three
point calibration was entered.
RENC2: Cal. Point 2
Weight Entered
A value for the second point in the
three point calibration was entered.
RENC4: Cal. Point 1
Weight Erased
The running average for point one of
the three point calibration was erased.
RENC5: Cal. Point 2
Weight Erased
The running average for point two of
the three point calibration was erased.
REND0: Ratio Check
Dispense
A ratio check shot was dispensed
from the ratio check calibration
screen.
REA00: Disp.
Occurred (Shot #)
A dispense has occurred of the given
shot number.
REH00: Gel Timer
Dispense
The gel timer expired and the system
automatically took the gel shot.
RER01: Shot Count
Reset
A counter from the shot counters
maintenance page was erased
RER02: Seq. Posi
-
tion Count Reset
A counter from the sequence counters
maintenance page was erased
RERA1: Red Material
Volume Reset
The resettable totalizer for the Red
material volume was reset to zero.
RERB1: Blue Mate
-
rial Volume Reset
The resettable totalizer for the Blue
material volume was reset to zero.
RERA2: Red Material
Weight Reset
The resettable totalizer for the Red
material weight was reset to zero.
RERB2: Blue Mate
-
rial Weight Reset
The resettable totalizer for the Blue
material weight was reset to zero.
RERA3: Red Cycle
Count Reset
The resettable cycle counter for the
Red pump was reset to zero.
RERB3: Blue Cycle
Count Reset
The resettable cycle counter for the
Blue pump was reset to zero.
REQU1: Settings
Downloaded
The system settings were successfully
transferred from the ADM to a USB
drive.
REQU2: Settings
Uploaded
The system settings file was success
-
fully transferred from the USB drive to
the ADM.
REQU3: Language
Downloaded
The custom language file was suc
-
cessfully transferred from the ADM to
a USB drive.
REQU4: Language
Uploaded
The custom language file was suc
-
cessfully transferred from the USB
drive to the ADM.
REQU5: Logs Down
-
loaded
The Error/Event and Shot data logs
were successfully transferred from the
ADM to a USB drive.
REAR0: Night Mode
Recirc On
While in night mode the system has
automatically entered a low recircula
-
tion mode and attempted to turn on all
enabled conditioning zones.
REBR0: Night Mode
Recirc Off
While in night mode the system has
automatically stopped the low recircu
-
lation mode and turned off all condi
-
tioning zones.
Event Code and
String
Triggers
Содержание HFRL
Страница 13: ...Warnings 3A2175Z 13...