Models
4
3A2175Z
Models
HFR-Laminate (HFRL)
HFRL models are designed for use with low viscosity, unheated urethane laminating adhesives at flow rates of up to
30 cc/sec (4 lb/min) @ 1500 psi (10 MPa, 103 bar).
** Cycle rate should be between 8 and 20 cycles per minute. Max flow rate is determined for continuous service at
120°F (39°C) at stated cpm and pressure. Higher cycle rates are possible at lower temperatures/pressures and
intermittent use. Lower cycle rates may be possible, but should be tested under application conditions.
†
Dispense rate in excess of max flow and pressure may result in an elevated temperature of the hydraulic system,
resulting in a thermal shutdown (T4H1). Other system models are available for sustained flow rates and pressures
in excess of above.
A Pump
Size
B Pump
Size
cc/cycle
Required cpm@
Flow**
Max Flow †
cc/sec (lb/min) @ 1500 psi (10 MPa, 103 bar)
Ratio
160
86
246
8
30 (4)
1.86
100
86
186
10
1.16
86
80
166
11
1.08
80
80
160
12
1.00
80
65
145
13
1.23
80
60
140
13
1.33
80
50
130
14
1.60
86
40
126
15
2.15
60
50
110
17
1.20
65
40
105
18
1.63
60
40
100
19
1.50
60
25
85
20
28 (3.7)
2.40
50
30
80
20
26 (3.5)
1.67
50
25
75
20
25 (3.3)
2.00
50
20
70
20
23 (3.1)
2.50
Содержание HFRL