Appendix D - ADM Error Codes
84
3A2175Z
Appendix D - ADM Error Codes
Error
Code Error Name Error Description
Error
Type
Cause
Solution
A4H3
Mix Head
Motor
Overload
Refer to AC Power Pack manual
DEH3 Soft Stop
Asserted
MBH3
Low Mix
Head Oil
Level
P1H3
Low
Accumulator
Pressure
P4H3
High
Accumulator
Pressure
T4H3
High Mix
Head Oil
Temp.
WDF3 M1 Material
Rod Shift Fail
WDD3 M1 Cleanout
Rod Shift Fail
0500
Invalid
Weight Cal.
Data
The three point calibration
data is invalid, system will
operate in weight mode but
will attempt to volumetrically
calculate weight. This will lead
to consistent shots which will
be offset for the desired
dispense amount.
Deviation Invalid data
Re-calibrate the machine
02D0 Low Flow
Advisory
Pump velocity is too low.
Advisory
Pump flow setpoint is
lower than one eighth of
the total pump volumes
Increase the pump flow setpoint
A4A6 Red Blanket
Overcurrent
An over current was detected
on the output
Alarm
Bad heaters
Measure resistance of heater
A4B5 Blue Blanket
Overcurrent
A4A3 Red Inline
Overcurrent
A4B1 Blue Inline
Overcurrent
A4A2 Red Hose
Overcurrent
A4B4 Blue Hose
Overcurrent
A4A7 Red Chiller
Overcurrent
High voltage
Measure voltage across the disconnect switch.
Voltage should measure between 190 and 264 Vac.
A4B8 Blue Chiller
Overcurrent
Shorted Temperature
Control Module
If temperature rises for a zone that has been
disabled, replace Temperature Control Module
A4H1 Motor Over
Current
High current has been
detected on a phase and has
been shutdown to prevent
damage
Alarm
Bad internal wiring of the
motor
Replace motor
Short circuit of motor
wiring
Check wiring to the motor to ensure no bare wires
are touching and that no wires are shorted to ground
A4M1 Motor Over
Current
Too much current is being
drawn from the wall
Alarm
Low voltage from the
wall during load
Make sure the supply line is properly sized for the
load and is above the minimum voltage requirements