Integration
80
333587B
Pump Error Codes
Pump Active Alarms
Bit
Number
Alarm
Code
Alarm Name
0
V1M_
Low Voltage P_
1
V4M_
High Voltage P_
2
T4M_
High Motor Temperature P_
3
T4J_
High Controls Temperature P_
4
WBD_
Encoder Hardware P_
5
WMN_
Software Mismatch P_
6
CCN_
Control Board P_
7
A4N_
High Motor Current P_
8
WMC_
Control Board P_
9
A4J_
High Motor Current P_
10
DD4_
Pump Diving P_
11
P4C_
High Pressure P_
12
P1C_
Low Pressure P_
13
F4D_
High Flow Rate P_
14
F1D_
Low Flow Rate P_
15
P6D_
Outlet Pressure Sensor P_
16
DKC_
Crossover Error P_
17
L1C_
Drum Empty P_
18
DB1_
Pump Not Primed P_
19
CCG_
Fieldbus Comm. Error P_
20
CAC_
Display Comm. Error P_
21
P6V_
Valve Pressure Sensor P_
22
WSN_
Invalided Style P_
23
WNC_
iQ Software Not Selected P_
24
WMH_
Control Board Off P_
25
-
Reserved
26
-
Reserved
27
-
Reserved
28
-
Reserved
29
-
Reserved
30
-
Reserved
31
-
Reserved
Pump Active Deviation
Bit
Number
Deviation
Code
Deviation Name
0
T2J_
Motor Temperatures Sensor P_
1
T3J_
Temperature Cutback P_
2
WSC_
Encoder Calibration P_
3
DD3_
Pump Diving P_
4
P3C_
High Pressure P_
5
P2C_
Low Pressure P_
6
F3D_
High Flow Rate P_
7
F2D_
Low Flow Rate P_
8
P6D_
Outlet Pressure Sensor P_
9
L2C_
Drum Low P_
10
DB2_
Pump Not Primed P_
11
-
Reserved
12
-
Reserved
13
-
Reserved
14
-
Reserved
15
-
Reserved
16
-
Reserved
17
-
Reserved
18
-
Reserved
19
-
Reserved
20
-
Reserved
21
-
Reserved
22
-
Reserved
23
-
Reserved
24
-
Reserved
25
-
Reserved
26
-
Reserved
27
-
Reserved
28
-
Reserved
29
-
Reserved
30
-
Reserved
31
-
Reserved