ADM Display Details
333587B
19
ADM LED Status Descriptions
ADM Icons
LED
Conditions
Description
System Status
Green Solid
Run Mode, System On
Green Flashing
Setup Mode, System On
Yellow Solid
Run Mode, System Off
Yellow Flashing
Setup Mode, System Off
USB Status (CL)
Green Flashing
Data recording in progress
Yellow Solid
Downloading information to USB
Green and Yellow Flashing
ADM is busy, USB cannot transfer information
when in this mode
ADM Status (CN) Green Solid
Power applied to module
Yellow Flashing
Active Communication
Red Steady Flashing
Software upload from token in progress
Red Random Flashing or Solid
Module error exists
Icon
Function
Alarm - See
Troubleshooting
, page
for more information.
Deviation - See
Troubleshooting
, page
for more information.
Advisory - See
Troubleshooting
, page
for more information.
Target for primary pressure and flow.
Only displayed in priming mode.
Communication Error
No issues found with parameter or
setting value
Missing or unexpected parameter or
setting value
System is processing request
(animated)
Pump position (animated). The pump
coupler will move up and down in real
time and indicate the approximate
position of the pump. The pump will
need to complete one full down stroke
upon each power cycle before the
position is valid.
Zone setpoint temperature showing the
temperature the zone heats too when
the heat is turned on.
Zone setback temperature showing the
setback the zone goes to when the heat
is in setback mode.
Icon
Function