![Graco Advanjet Diaphragm-Jet HV-2000 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/graco/advanjet-diaphragm-jet-hv-2000/advanjet-diaphragm-jet-hv-2000_setup-and-operation_2251220006.webp)
Page 6 of 60
Advanjet HV-2000C Jet Controller Setup and Operation
3A5856A
1. Introduction and Specifications
1.1
Advanjet HV-2000/2000C Overview
Advanjet HV-2000 non-contact jetting technology is a major leap in liquid dispensing.
The non-contact jetting is fast, allowing dispensing rates up to 300Hz. The user can
modify the drop size
±
20% from its nominal size, allowing a wide range of adjustability.
The simplicity of HV-2000 is also evident in its ease of cleaning, since all parts that
touch the fluid are easily removed.
The Advanjet HV-2000C controller provides timing signals as well as pneumatic and
electrical resources for the Advanjet HV-2000 Jet Valve.
The HV-2000C provides timing signals to drive a rapid-response solenoid valve
in the HV-2000 Jet Valve. Its internal computer remembers and executes a
variety of operational sequences. The controller can respond to actuation signals
from either a front panel switch or from an external switch.
The HV-2000C provides regulated, pressurized air for the fluid pressure and jet
pressure of the HV-2000 Jet Valve.
The HV-2000C provides electrical power to a heater element in the HV-2000 Jet
Valve, and controls the temperature of the
valve’s heater by monitoring a
resistance temperature detector (RTD) sensor in the HV-2000 Jet Valve.