Advanjet HV-2000C Jet Controller Setup and Operation
Page 13 of 60
3. Using the HV-2000C Controller Front Panel
Figure 3-1: HV-2000C Front Panel
3.1
Jet and Fluid Pressure Regulators
The HV-2000C controller has two integrated air
regulators (see Figure 3-2) that control the pressure to
the Jet and the Fluid supply. Turn the knob clockwise to
increase and counterclockwise to decrease. Digital
gauges indicate the pressure levels; the Jet Pressure
gauge is pictured below. The default pressure unit on
the HV-2000C is psi (1 psi = 0.00689 MPa). Details
from the pressure regulator manufacturer are in
Appendix 3: Digital Pressure Gauge.
The Air Switch allows the operator
to instantly turn the Fluid Pressure
ON
or
OFF.
This
is
very
convenient when changing fluid or
cleaning the jet.
JET
PRESSURE
GAUGE
TRIGGER
BUTTON
RS-232
PORT
KEYPAD
LCD
DISPLAY
TRIGGER LED
TEMPERATURE
CONTROLLER
JET PRESSURE
CONTROLLER
FLUID PRESSURE
CONTROLLER
POWER
SWITCH
AIR
SWITCH
FLUID
PRESSURE
GAUGE
Figure 3-2:
Pressure Regulators and
Air Swicth
Figure 3-3:
Jet Pressure Gauge
Figure 3-4:
Air Switch