![Graco Advanjet Diaphragm-Jet HV-2000 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/graco/advanjet-diaphragm-jet-hv-2000/advanjet-diaphragm-jet-hv-2000_setup-and-operation_2251220033.webp)
3A5856A
Advanjet HV-2000C Jet Controller Setup and Operation
Page 33 of 60
7.3
Recipe Timing Commands
ST
Set Recipe Timers
#RecipeID,#Refill,#0,#0,#0,#0,#Dwell;
The
ST
function configures the timing values for the recipe. #RecipeID numbers 0 to 5
correspond to Recipes 1 to 6.
#RecipeID 0
#RecipeID 1
2
#RecipeID 2
3
#RecipeID 3
4
#RecipeID 4
5
#RecipeID 5
6
Figure 7-1 - #RecipeID 0
– 5
Corresponds to Recipe #1 - 6
Seven parameters are required for this function, defined as follows:
1
# nRecipeID
Identifies the recipe; it must be between
0 and 5
.
2
# Refill
Specifies the Refill Time in
0.1 msec
units.
3 - 6
#0, #0, #0, #0
Four reserved timer values; they must all be
0
.
7
# Dwell
Specifies the Dwell Time in
0.1 msec
units.
Example #1: ST 0,18,0,0,0,0,32;
Sets the first recipe, Recipe #1
Refill Time is 1.8 msec
Dwell Time is 3.2 msec
The Refill Time plus the Dwell Time set the single drop cycle time to 5msec
(1.8 +3.2) resulting in a drop frequency of 200 drops per second.
Example #2: ST 3,50,0,0,0,0,150;
Sets Recipe #4
Refill Time is 5 msec
Dwell Time is 15 msec
The Refill Time plus the Dwell Time set the single drop cycle time to 20msec
(5+15) resulting in a drop frequency of 50 drops per second