Changing Empty Pails
(continued)
6. Lower the follower into the drumpail:
a. Move the ram hand valve lever to the DOWN
position.
b. Check the pail position as the follower lowers.
If necessary, stop lowering the follower before
contacting the pail, and adjust the pail position
to align the pail with the follower plate.
c. Continue lowering the follower. As the follower
enters the pail, loosen the air bleed stick.
Loosening the bleed stick allows trapped air
between the follower plate and the top of the
material to escape.
d. When air stops exhausting from the bleed stick
port, replace and tighten the bleed stick.
7. Adjust the ram air pressure for normal operation.
8. Bleed, from the pump, the air that was introduced
during the pail change:
a. Place a waste container under the pump bleed
port.
b. Open the bleed port and turn on pump air
pressure.
c. Allow material to flow from the bleed port until
it is air-free.
d. Shut off air to the pump and close the bleed
port.
e. Turn air on to the pump and set the pump air
regulator for normal operation.
9. Resume normal operation.
Shutdown
1. Turn the CONTROL ON switch to OFF.
2. Turn OFF the main electrical disconnect.
3. Move the ram hand valve lever (Fig. 3 on page 21)
to the OFF position. Shut off the air supply to the
ram and pump.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure
(page 21).
4.
Relieve the pressure.
Emergency Stop
1. On the electrical control panel:
a. Turn OFF the main electrical disconnect.
b. Turn the CONTROL ON switch to OFF.
2. Stop the pump by closing the Bleed-type Master
Air Valve closest to the motor’s air inlet, (C) in Fig.
1, on page 9.
3. Stop the ram from moving by:
a. Closing the ram air lock-out valve.
b. Moving the ram hand valve lever (Fig. 3 on
page 21) to the OFF position.
Содержание 918334
Страница 12: ...12 310528 Notes...
Страница 36: ...36 310528 Service Fig 10 240 Volt Ram Plate Assembly Wiring 9599A 3L1 3L2 3L3 5L1 5L2...
Страница 37: ...310528 37 Service Fig 11 To Ram Junction Box 3L1 3L2 3L3 5L1 5L2 5L3 480 575 Volt Ram Plate Assembly Wiring...
Страница 40: ...40 310528 Notes...
Страница 44: ...44 310528 Notes...
Страница 52: ...52 310528 Notes...
Страница 65: ...310528 65 Parts Models 617349 480 VAC and 617485 240 VAC 4 zone Electrical Control Panel exterior...
Страница 67: ...310528 67 Schematics Electrical Control Panel and Wiring Parts and Description 617300 Page 1 9604A...
Страница 68: ...68 310528 Schematics 617300 Page 2 9605A...
Страница 69: ...310528 69 Schematics 617485_1 9606A...
Страница 70: ...70 310528 Schematics 617485_2...
Страница 71: ...310528 71 Schematics 617484 Page1 9608A...
Страница 72: ...72 310528 Schematics 617484 Page2 9609A...
Страница 73: ...310528 73 Schematics 617349 Page1 9689A...
Страница 74: ...74 310528 Schematics 617349 Page 2 9690A...
Страница 84: ...84 310528 Appendix New Style Temperature Controller Settings List...