310528
21
Operation
Pressure Relief Procedure
MOVING PARTS HAZARD
Follow the
Pressure Relief Procedure
below before checking or repairing the
ram or any other part of the system and
when shutting down the system. Keep hands and
fingers away from the follower plate, fluid pump
inlet, and lip of the fluid container when raising or
lowering the ram to reduce the risk of pinching or
amputating hands or fingers.
During operation, also keep hands and fingers
away from limit switches to reduce the risk of
pinching or amputating hands or fingers.
WARNING
WARNING
The material and equipment will be
hot!
To reduce risk of injury, wear eye
protection, gloves and protective clothing
when installing, operating, or servicing
this dispensing system.
WARNING
HIGH PRESSURES CAN CAUSE SE-
RIOUS PERSONAL INJURY.
Be sure
to
OPEN THE DISPENSE VALVE
DURING SYSTEM HEATUP
to allevi-
ate pressure which might occur in the system due
to material expansion.
WARNING
INJECTION HAZARD
The system pressure must be manually
relieved to prevent the system from
starting or spraying accidentally. Fluid
under high pressure can be injected through the
skin and cause serious injury. To reduce the risk of
an injury from injection, splashing fluid, moving
parts, follow the
Pressure Relief Procedure
whenever you:
D
are instructed to relieve the pressure
D
stop spraying/dispensing
D
check or service any of the system equipment
D
install or clean the spray tip/nozzle
This procedure describes how to relieve pressure for
the supply unit. Use this procedure whenever you shut
off the dispenser/sprayer and before checking or
adjusting any part of the system, to reduce the risk of
serious injury.
1. Lock the gun/valve trigger safety.
2. Shut off the main air supply to the pump.
3. Close all air bleed valves.
4. Unlock the gun/valve trigger safety.
5. Hold a metal part of the gun/valve firmly to the side
of a grounded metal drumpail, and trigger the
gun/valve to relieve pressure.
6. Lock the gun/valve trigger safety.
7. Have a container ready to catch the drainage, then
open the drain valve or pump bleed valve.
8. Leave the drain valve open until you are ready to
spray/dispense again.
If you suspect that the spray tip/nozzle or hose is
completely clogged, or that pressure has not been fully
relieved after following the steps above, very slowly
loosen the nozzle retaining nut or hose end coupling to
relieve pressure gradually, then loosen completely.
Now clear the tip/nozzle or hose.
9. If you want to relieve pressure in the ram, see the
Ram Pressure Relief Procedure
on page 31.
Raising and Lowering the Ram
The ram hand valve on the ram air control has 3
positions [Fig. 3 (4-regulator version shown)]:
D
Ram UP raises the ram
D
Ram DOWN lowers the ram
D
Ram OFF puts the ram in “neutral.” Moving the
hand valve to OFF does not change the position of
the ram, but it stops the air pressure from attempt-
ing to move the ram either up or down.
Fig. 3
Ram OFF (neutral)
Ram UP
Ram DOWN
7979A
Содержание 918334
Страница 12: ...12 310528 Notes...
Страница 36: ...36 310528 Service Fig 10 240 Volt Ram Plate Assembly Wiring 9599A 3L1 3L2 3L3 5L1 5L2...
Страница 37: ...310528 37 Service Fig 11 To Ram Junction Box 3L1 3L2 3L3 5L1 5L2 5L3 480 575 Volt Ram Plate Assembly Wiring...
Страница 40: ...40 310528 Notes...
Страница 44: ...44 310528 Notes...
Страница 52: ...52 310528 Notes...
Страница 65: ...310528 65 Parts Models 617349 480 VAC and 617485 240 VAC 4 zone Electrical Control Panel exterior...
Страница 67: ...310528 67 Schematics Electrical Control Panel and Wiring Parts and Description 617300 Page 1 9604A...
Страница 68: ...68 310528 Schematics 617300 Page 2 9605A...
Страница 69: ...310528 69 Schematics 617485_1 9606A...
Страница 70: ...70 310528 Schematics 617485_2...
Страница 71: ...310528 71 Schematics 617484 Page1 9608A...
Страница 72: ...72 310528 Schematics 617484 Page2 9609A...
Страница 73: ...310528 73 Schematics 617349 Page1 9689A...
Страница 74: ...74 310528 Schematics 617349 Page 2 9690A...
Страница 84: ...84 310528 Appendix New Style Temperature Controller Settings List...