6. Apply a thin coat of lithium grease to the threads of
the M10 hex head cap screw (608) and 10MM seal
washer (607). Apply a thin coat of lithium grease to
the threads of the SST M10 plug (612) and copper
washer (611) and install into the and install into the
SST single inlet adapter (602). Torque to 15 ft-lb
(20.34 N•m). If sensors are an option, apply a thin
coat of lithium grease to the threads of the RTD
sensor (609) and pressure transducer (610) if used
and their 10MM seal washers (607). Install the
sensors and torque to 15 ft-lb (20.34 N•m).
7. Connect solenoid valve cable connections (617)
and if equipped, sensor wires from the RTD sensor
(609) and /or pressure transducer (610) to the dual
cable connector (614). See
Pin Connections for Temperature and Pressure
Sensors. Model No. 25T992, 25T993, 25T995 and
25T996
8. Install dual cable connector (614) into dual
connector bracket (616) and tighten nuts. Attach
connector bracket to the swivel housing assy (511)
with two M5 SHCS screws (615) and torque to 57.5
in-lb (6.5 N•m). See F
F
IG
. 35
517
513
518
617
515
516
514
F
IG
. 36
607
612
611
608
609
602
610