Installation
10
3A8476A
Cable Connections
NOTE:
Cables and hoses are attached only after SST
Switch 3D Gun is bolted to robot.
Connect cable (1001) for all SST Switch 3D Gun
models, and (1003) for SST Switch 3D guns with
sensors. Then connect other end of the cables by
making the appropriate connections to the robot’s
See the
table page 3, for the cable type needed
for your SST Switch 3D Gun mode.
Hose Connections
The air supply is connected to the SST Switch 3D Gun
with an 8 mm polyurethane hose to the elbow swivel
fitting (512) on the side of the swivel housing (511).
Customer must install air bleed valve between air supply
and SST Switch 3D Gun connection. See F
The material supply hose connects to the SST Switch
3D gun using a customer supplied fitting. The inlet
PCF Installation
NOTE:
The following installation is for SST Switch 3D
Guns that use a Precision Continuous Flow Unit (PCF).
See
PCF to 3D Gun Cable Kit 25U441
parts.
1. Remove the PCF cover (A).
2. Disconnect the dispense valve air solenoid cable
from FCM port 1(B). Secure the loose end of the
cable to the PCF fluid mounting plate (C).
3. Disconnect the regulator air line (D) from the
incoming air wye fitting (E).
4. Disconnect the incoming air wye fitting (D) from the
incoming air elbow fitting (F). Secure the incoming
air wye fitting to the PCF fluid mounting plate (C).
See F
F
IG
. 5
F
IG
. 6
NOTICE
Only use air fittings that are rated at a temperature
equal to or higher than the operating temperature of
the fluid dispensing system. Lower rated air fittings
could melt and cause damage to the SST Switch 3D
Gun.
801
902
707
901
105
Connect to robot control cabinet
(not shown).
1001 and 1003 if
equipped with
sensors
F
IG
. 7
511
Customer supplied
material hose.
Customer
supplied 8 mm
air hose.
Customer supplied
bleed valve
512