![Graco 24N950 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/graco/24n950/24n950_operation-repair-parts_2251626018.webp)
Storage
18
332119E
Storage
1. Clean field marker. See
Shutdown and Cleaning
,
page 15.
2. Lift prime/spray valve (D) UP to the prime position.
3. Pour a small amount of Pump Armor into bottom of
paint hopper.
4. Push spray button (A) to pump the material.
5. Press spray button to stop when Pump Armor flows
through prime hose.
6. Move prime/spray valve (D) DOWN to the spray
position.
7. Press spray button to spray material.
8. Press spray button to stop pump when Pump Armor
sprays through tip.
9. Plug charger into field marker. See
Charging the
Battery
, page 8. Charge to full charge and disconnect.
10. Store field marker indoors in a cool, dry place.
Always store field marker with some Pump Armor in
the paint pump/hopper. Never store field marker dry
or with paint in the pump/hopper.
NOTICE
Failure to store field marker with Pump Armor will result
in operational problems the next time you spray. Always
circulate Pump Armor through the field marker after
cleaning.
Water left in the field marker will damage
the pump due to freezing.
ti20183a
D
ti20212a
A
ti20184a
D