Common Procedures
10
332119E
Common Procedures
Prime/Spray Valve
Follow the
Pressure Relief Procedure
whenever you see this symbol.
Pressure Relief Procedure
1. Put prime/spray valve (D) UP to release pressure.
Install Spray Tip/Guard
Assembly (if not installed)
1. Put prime/spray valve (D) UP to release pressure.
2. Screw spray/tip guard assembly (G) onto field marker.
Tighten retaining nut until completely engaged with
field marker. Do not overtighten nut.
Do not operate or spray near children. Do not aim the
field marker at, or spray any person or animal. Keep
hands and other body parts away from the discharge.
For example, do not try to stop the paint flow with any
part of the body.
This field marker builds up an internal pressure of
1200 psi (8.3 MPa, 83 bar) during use. Follow this
Pressure Relief Procedure
whenever you stop
spraying and before cleaning, checking, servicing, or
transporting equipment to prevent serious injury.
UP position
(For priming and releasing
DOWN position
(Ready to spray)
ti14999a
pump pressure)
ti20183a
ti20184a
ti20183a
D
Perform the
Pressure Relief Procedure
before
installing spray tip/guard assembly.
Do NOT place hands in front of tip.
ti20183a
D
ti14997a
ti20215a
G