Appendix B - ADM Run Screens Overview
3A2806A
35
Appendix B - ADM Run Screens Overview
For other screen not mentioned, refer to the HFRL and
HFRS, Setup-Operations manual.
Home Screen, Refill Disabled
If refill is Disabled, the home screen will not show a
graphic display of the reservoirs.
Home Screen, Refill Enabled
When the level sensors are active and both reservoirs
have material, the display looks as above. The stack
light will illuminate a solid green (Unless another error is
present).
Home Screen, Low Level - A (Red) Side
When a low level on the RED side is sensed, the pop up
error code appears and the active error display reads
“Red Low Material Level”. The light stack will flash yel-
low, and the audible alarm will sound. When this error
occurs, the machine will continue to dispense when a
start is initiated, unless the “Low Material Disables Dis-
pense” flag is set.
Refer to
to configure the machine
to stop dispensing when a low level sensor is triggered.
When the level condition is acknowledged by the opera-
tor (by hitting the enter key), but not cleared; the audible
alarm will stop, and the pop up window will disappear.
The active error display will still indicate a low level con-
dition, and the stack light will continue to flash yellow,
unless the low level condition has been corrected.