Setup
14
3A2806A
Setup
Calibrate Barrel Style Level
Sensors
1.
Locate the calibration button on the sensor (11)
closest to the electrical connector through one of
the four holes of the sensor well housing (CA).
2.
If the calibration button cannot be seen through one
of the four holes in the sensor well, rotate the sen-
sor.
a.
Loosen the sensor well nut (CC).
b.
Rotate sensor until the calibration button can be
seen through one of the four holes in the sensor
well housing.
c.
Tighten sensor well nut.
d.
Press and hold the button down with the ball
end of an allen wrench for two seconds. The
light will flash slowly and then go out.
3.
Test for proper sensor function.
a.
Loosen the sensor well nut.
b.
Back the sensor out of the well. The sensor
should sense the housing wall.
Set the ADM to Recognize the
Feed System Kit
1.
Navigate to the ADM Supply Screen.
2.
Press .
3.
For the appropriate chemical side, select “
Monitor
”
within the Refill Setting selection box.
NOTE:
Select “
Disabled”
if the level system is not being
used.