Appendix A - ADM Setup Screens Overview
32
3A2806A
Appendix A - ADM Setup Screens Overview
For other screen not mentioned, refer to the HFRL and
HFRS, Setup-Operations manual.
Supply Screen
This screen allows the user to specify the operating
parameters for off-board, integrated tanks and indicate
which positions have level sensors installed.
Activate at least 2 level sensors for each reservoir or the
level sensor functions will be disabled.
For a single low sensor in each drum feed, configure as
shown below. (Activate mid and low sensors, and set
refill setting to monitor).
Advanced Screen 1
This screen allows the user to set the language, date
format, current date, time, setup screens password,
screen saver delay, and turn on or off silent mode.
•
Time:
formatted in 24 hour time.
•
Password:
Enables the setup screens to be pass-
word protected. Entering “0000” disables the fea-
ture.
•
Screen Saver:
Enter the amount of time until the
backlight turns off. Entering “0” leave it constantly
on.
•
Silent Mode:
Check this box to turn off the buzzer
for key presses.
Advanced Screen 2
This screen allows the user to set the units of measure.