Appendix A - Modbus Variable Map
Address
Address
Address
Description
Description
Description
Permissions
Permissions
Permissions
Units
Units
Units
Low
Low
Low
High
High
High
Notes
Notes
Notes
403150
Unused
Read/Write
403152
Flow Rate
maximum setpoint
limit
Read/Write
cc/min
0
9999
403154
Flow Rate
minimum setpoint
limit
Read/Write
cc/min
0
9999
403156
Atomizing Air
percentage drive
maximum
Read/Write
Percent
0
0x63E667
Scaled as 1 % = 65536
403158
Atomizing Air
percentage drive
minimum
Read/Write
Percent
0
0x63E667
Scaled as 1 % = 65536
403160
Flow Control PID
gain percentage
Read/Write
Percent
1
100
403162
System Idle
timeout
Read/Write
minutes
0
99
0 = Not used
403164
Dose Time timeout Read/Write
seconds
0
99
0 = Not used
403166
Job Attribute code
Read/Write
Value
0
32-bit
403168
Job trigger time
Read/Write
ms
0
32-bit
403170
Unused
403172
Unused