Deviations
Deviations
Deviations and
and
and Advisories
Advisories
Advisories
Code
Code
Code
Icon
Icon
Icon
Summary
Summary
Summary
Description
Description
Description
Solution
Solution
Solution
SN
Minimum
Fill
Volume
Alarm only. Active when the
user-set fill volume is not achieved
in a fill cycle.
Increase fill drive percentage,
fill time, or check fluid supply
(
Setup Screen 10: PID Data, page 51
).
Press
to clear alarm.
SP
Minimum
Flush
Volume
Alarm only. Active when the
user-set flush volume is not
achieved in a flush cycle.
Increase flush drive percentage,
flush time, or check fluid supply
(
Setup Screen 11: Fill Mode, page 51
).
Press
to clear alarm.
B4
Job
Dispense
High
Alarm only. Active when the
logged job spray volume is more
than the threshold setpoint.
Adjust flow rate, spray time, maximum
volume limit, or disable alarm
(
Setup Screen 1: Job Target, page 43
).
Press
to clear alarm.
B1
Job
Dispense
Low
Alarm only. Active when the
logged job spray volume is less
than the threshold setpoint.
Adjust flow rate, spray time, minimum
volume limit, or disable alarm
(
Setup Screen 1: Job Target, page 43
).
Press
to clear alarm.
F6
Runaway
Flow
Deviation only. Active when using
flow control and the flow target is
not achievable.
Determine cause of fluid control failure.
Press
to clear alarm.
P6
Runaway
Pressure
Deviation only. Active when using
pressure or flow control and the
pressure target is not achievable.
Determine cause of fluid control failure.
Press
to clear alarm.
EU
System
Idle
Advisory only. Active when in
Dispense mode and the gun
trigger has not been activated for
the user-set timeout time. Fluid
pressure is dropped to zero.
Dispense pressure will resume immediately
once the gun trigger is activated. The
advisory will automatically clear. Press
to clear alarm.
MF
Mainte-
nance
Counter
Advisory only. Active when the
maintenance totalizer reaches the
user-set maintenance target.
Perform maintenance. Reset to zero
using
(
). Press
to clear
alarm.
G2
Gun Off
Setpoint
Advisory only. The flow rate
setpoint was changed to a lower
value while the gun was off.
Instead of predicting a pressure
target, the system will predict a
current output target to the I/P. It
may take extra time to stabilize in
this situation.
Activate spraying. Press
to clear alarm.
3A6948A