This screen contains the Atomization Air percentage
input limits, the System Idle timeout, and the Dose
Time timeout.
Table
Table
Table 13
13
13 Setup
Setup
Setup Screen
Screen
Screen 6
6
6
Description
Description
Description
Examples
Examples
Examples
Empty
With data
Key
Key
Key
Enter the screen to set or change
preferences.
Press to activate a field for editing or
to accept the highlighted selection on
a menu.
Move to the right when editing number
fields. Press again to accept the entry
when all digits are correct.
Set your desired maximum (first data
field) and minimum (second data field)
atomizing air percentage. The system’s
atomizing air setpoint cannot be set
outside of this range.
The number of minutes with the
system in Dispense mode with no gun
trigger activation before it sets the fluid
regulator to zero. Once the gun trigger
is activated the regulator will be driven
to the previous value.
The number of seconds with the
system in Dispense mode with no
detected fluid flow while the gun trigger
is activated. The alarm will shut down
the system.
Exit data editing.
Move between Setup Screens, fields
on a screen, or to increment/decrement
the digits when editing number fields.