Grounding
Grounding
Grounding
The equipment must be grounded to reduce the
risk of static sparking and electric shock. Electric
or static sparking can cause fumes to ignite or
explode. Improper grounding can cause electric
shock. Grounding provides an escape wire for the
electric current.
1.
Power
Power
Power Supply
Supply
Supply Modules
Modules
Modules 16M167
16M167
16M167 and
and
and 26C724:
26C724:
26C724:
Refer to the IS Power Supply Modules manual.
2.
ProControl
ProControl
ProControl 1KE
1KE
1KE Plus
Plus
Plus ADCM:
ADCM:
ADCM: Connect a ground
wire to the screw on the top of the bracket.
Connect the other end to a true earth ground. In
an IS system, the ProControl 1KE Plus ADCM
is also grounded by connection to the grounded
power supply.
3.
External
External
External Mounted
Mounted
Mounted Flow
Flow
Flow Meter:
Meter:
Meter: Follow the
instructions in manual 308778 (G3000, S3000,
G250) or manual 313599 (Coriolis) to ground
the flow meter and check its electrical grounding
continuity.
4.
Fluid
Fluid
Fluid and
and
and Air
Air
Air Control
Control
Control Panel:
Panel:
Panel: Connect a ground
wire to the screw on the 1KE Plus fluid panel.
Connect the other end to a true earth ground.
5.
Fluid
Fluid
Fluid Supply:
Supply:
Supply: Ground the fluid supply system.
Cable
Cable
Cable Connections
Connections
Connections to
to
to the
the
the Advanced
Advanced
Advanced Display
Display
Display Control
Control
Control Module
Module
Module (ADCM)
(ADCM)
(ADCM)
Port
Port
Port
Description
Description
Description
Connection
Connection
Connection
1
Fiber Optic Receiver
Red Lead from TX on Fiber Optic Converter (PN 16K465) or from Port 6
on another ProControl 1KE Plus (or Informer)
2
Fiber Optic Transmitter
Black Lead to RX on Fiber Optic Converter (PN 16K465) or to Port 5 on
another ProControl 1KE Plus (or Informer)
3
Power
From Power Supply
4
Digital Input/Output
To/From Meter and Light Tower (Accessory)
5
Fiber Optic Receiver
Black Lead from Port 2 on another ProControl 1KE Plus (or Informer)
6
Fiber Optic Transmitter
Red Lead to Port 1 on another ProControl 1KE Plus (or Informer)
7
Analog Input
To/From Pressure Transducer Cable
8
Flow Control
To/From Flow Control Cable
9
Atomizing Air Control
To/From Atomizing Air Control Cable
10
Analog Input
From Air Flow Switch (AFS) or Gun Trigger
3A6948A
23