Appendix A - Modbus Variable Map
Run
Run
Run Registers
Registers
Registers
All registers are 32-bit.
Address
Address
Address
Description
Description
Description
Permissions
Permissions
Permissions
Units
Units
Units
Low
Low
Low
High
High
High
Notes
Notes
Notes
402000
Date, Year
Read/Write
YY
1
99
Limited to 2099
402002
Date, Month
Read/Write
MM
1
12
402004
Date, Day
Read/Write
DD
1
31
402006
Time, Hour
Read/Write
HH
0
23
402008
Time, Minute
Read/Write
MM
0
59
402010
Time, Second
Read/Write
SS
0
59
402012
Alarms Needing
Acknowledgment
Read/Write
Bitfield
0
32-bit
See
402014
Current Grand Total
Read
cc
0
32-bit
402016
Current Batch Total
Read/Write
cc
0
999999
Write 0 to reset
402018
Current Maintenance Total Read/Write
cc
0
9999999
Write 0 to reset
402020
Current Flow Rate
Read
cc/min
0
65535
402022
Current Pressure
Read
bar
0
32-bit
Scaled as 1 bar =
65536
402024
Unused
402026
Calibration Mode
Read/Write
Bit
0
1
0 = Off
1 = On
402028
Calibration, Measured
Volume
Read/Write
cc
0
32-bit
402030
Calibration, Actual
Dispensed Volume
Read/Write
cc
0
32-bit
402032
Dispense Mode
Read/Write
Selection
0
3
0 = Standby
1 = Flush
2 = Fill
3 = Dispense
402034
Gun Trigger On Time
Read
ms
0
32-bit
402036
Current Job Spray Total
Read
cc
0
24-bit
402038
Current Job Flush Total
Read
cc
0
24-bit
402040
Current Job Number
Read/Write
Value
0
32-bit
Automatically
increments
402042
Job Attribute
Read/Write
Value
0
32-bit
Use for identification
of the user, station,
part, etc.
402044
Job Gun Trigger Time
Read
ms
0
32-bit
402046
Unused
402048
Unused
82
3A6948A