Air
Air
Air Connections
Connections
Connections
Connect incoming air supply to the air supply shut-off
valve (L) 1/4 npt (f). (See
NOTICE
NOTICE
NOTICE
To avoid damage to the I/P transducer, use clean,
dry, oil-free air, filtered through at least a 40 micron
filter.
See
Technical Specifications, page 88
, for air
pressure and consumption ratings. The I/P
transducer exhausts a small amount of air whenever
air is connected, regardless of whether the system is
operating. Refer to your applicator gun air pressure
and consumption ratings and size your air supply
accordingly.
The ProControl 1KE Plus uses an Air Flow Switch
(AFS) to detect when the applicator gun is triggered.
Do not bypass the AFS. See
for an alternate gun trigger air pressure switch that
can be used in place of the provided AFS.
NOTE:
NOTE:
NOTE:
• The side port (AH) on the fluid regulator
can be used for high-speed flushing with an
independent air source. Set the air pressure
higher
higher
higher than the top port (AD) air pressure. See
Setup Screen 11: Fill Mode, page 51
, and
Setup Screen 12: Flush Mode, page 52
, for
the preferred method of controlling fill and flush
pressure.
• Flushing air pressure must be removed from the
side port (AH) to return to the previous flow setting.
24
3A6948A