Setup
Setup
Setup Screen
Screen
Screen 10:
10:
10: PID
PID
PID Data
Data
Data
Key
Key
Key
Enter the screen to set or change
preferences.
Press to activate a field for editing or
to accept the highlighted selection on a
menu.
Move to the right when editing number
fields. Press again to accept the entry
when all digits are correct.
Pressure control loop.
Flow control loop.
Proportional gain.
Integral gain.
Derivative gain.
First box displays the current gain the
system is operating, this number will
decrease as they system approaches its
flow target and will increase if the flow
diverges from target.
The second box is editable and is the
lowest gain the system will use. Higher
numbers will increase sensitivity but may
cause errors in certain situations such
as gun feathering and very short trigger
times.
Exit data editing.
Move between Setup Screens, fields on
a screen, or to increment/decrement the
digits when editing number fields.
Setup
Setup
Setup Screen
Screen
Screen 11:
11:
11: Fill
Fill
Fill Mode
Mode
Mode
Use this screen to set up the parameters for Fill
Mode. When set, the Minimum Fill Volume is
checked against the amount of material that flowed
during the Fill process. The “SN” Minimum Fill
Volume alarm is set if this isn’t achieved. Selection of
Dispense Mode is not allowed until the programmed
Minimum Fill Volume is reached.
Key
Key
Key
Enter the screen to set or change
preferences.
Press to activate a field for editing or
to accept the highlighted selection on
a menu.
Move to the right when editing number
fields. Press again to accept the entry
when all digits are correct.
Set fluid regulator to a percentage
open.
Set a fill duration time. The first box
displays the remaining time when a Fill
Mode is active.
Minimum Fill Volume. Set to “0” to
disable this feature.
Exit data editing.
Move between Setup Screens, fields
on a screen, or to increment/decrement
the digits when editing number fields.
3A6948A
51