Troubleshooting
32
311075ZAB
Troubleshooting Chart
PROBLEM
CAUSE
SOLUTION
Reactor E-10 does not operate.
No power.
Plug in power cord.
Cycle motor power off, then on to
reset breaker.
Motor does not operate.
Power turned on with function knob
set to a run position.
Set function knob to Park
, then
select desired function.
Loose connection on control board.
Check connection at J11 (120 V) or
J4 (240 V). See
page 41.
Worn brushes.
Check both sides. Replace brushes
worn to less than 1/2 in. (13 mm),
see
Broken or misaligned brush springs.
Realign or replace, see
Brushes or springs binding in brush
holder.
Clean brush holder and align brush
leads for free movement.
Shorted armature.
Replace motor, see
page 46.
Check motor commutator for burn
spots, black pitting, or other damage.
Remove motor. Have motor shop
resurface commutator, or replace
motor, see
Failed control board.
Replace board. See
,
page 41.
Fan not working.
Loose fan cable.
Check that cable is connected at fan
and at J9 on control board. See
page 47 and
, page
Defective fan.
Test and replace if necessary, see
Pump output low.
Plugged fluid inlet strainer.
Clear, see
, page 27.
Plugged disposable mixer.
Clean or replace.
Leaking or plugged piston valve or
intake valve in displacement pump.
Check valves. See your pump
manual.