96
User Manual
CAN Trigger and Serial Decode
Please take the order of “
Setup for CAN Signals
”, “
CAN Triggering
” and “
CAN Decode
”
to trigger and decode the signals.
Setup for CAN Signals
Setup consists of connecting the oscilloscope to a CAN signal, using the SINGAL menu to
specify the signal source, threshold voltage level, baud rate, and sample point.
To set up the oscilloscope to capture CAN signals.
1. Press
Decode
on the front panel to enter the DECODE function menu.
2. Press Serial and select the desired slot (Serial 1 or Serial 2).
3. Press
Decode
softkey and select CAN with the
Universal Knob
, and then push down
the
Universal Knob
to confirm.
4. Press the
Signal
softkey to enter the CAN SIGNAL menu.
Figure 53 CAN SIGNAL Menu
5. Press
CAN-H
or
CAN-L
; then, select the channel for the CAN signal.
6. Press the
Threshold
softkey; then, turn the
Universal Knob
to select the CAN signal
threshold voltage level. The threshold voltage level is used in decoding, and it will
become the trigger level when the trigger type is set to the selected serial decode slot.
7. Press the
Back
key to return to the DECODE menu.
8. Press the
Configure
softkey to enter the BUS CONFIG menu.
9. Press the
Baud
softkey; then, turn the
Universal Knob
to select the baud rate that
matches your CAN bus signal. The CAN baud rate can be set to predefined baud
rates from 5 kb/s up to 1 Mb/s or a custom baud rate from 1b/s to 1 Mb/s. If the desired
baud rate is not listed, select
Custom
on the
Baud
softkey, and then press the
Custom
softkey and turn the
Universal Knob
to set the desired baud rate.
10. Press the
Decode Source
softkey to set the decode source that matches the single
•
CAN_H
— The actual CAN_H differential bus.
CAN_L
— The actual CAN_L differential bus signal.
CAN_H-CAN_L
— The CAN differential bus signals connected to an analog
source channel using a differential probe. Connect the probe's positive lead to the
dominant- high CAN signal (CAN_H) and connect the negative lead to the
dominant- low CAN signal (CAN_L).
•
All Rights Reserved - General Polytronic Systems Ltd., London