GMC-I Messtechnik GmbH
27
UI
_
– U/I Min-Max Measured Value Memory (MINMAX)
Functions
•
Save
minimum
and
maximum
measured voltage and current
values.
•
Reads out stored values for
Umin
,
Umax
,
Imin
and
Imax
at the
display, or via the computer interface.
•
The MINMAX function can be temporarily set to
OFF
, for
example before deactivating the output when changing
devices under test. Stored values are then no longer updated,
nor are they automatically reset.
•
Stored Min-Max values can be read out regardless of the
status selected for the
MINMAX
function.
•
Stored Min-Max values can always be reset with the
UI
_
RST
command.
•
Stored Min-Max values can also be reset with the
*RST
command, or with the key combination
<CE/LOCAL> +
<ENTER>
(
= RESET
).
•
The status of the
MINMAX
function is also saved to
SETUP
memory by pressing the
SAVE
key.
•
If the
Pon
function is set to
SbY
or
rcl
, the MINMAX function is
activated upon power-up, but previously measured Min-Max
values are lost when the KONSTANTER is switched off.
•
The
MINMAX
function can also be controlled via the
trigger input
at the analog interface.
Setting Parameter
☞
OFF:
Storage of Min-Max values is deactivated
☞
ON:
Storage of Min-Max values is activated
☞
RST:
contents in the Min-Max memory are reset or replaced
with the momentary measured value:
Umin = Uout
Umax
= Uout
Imin
= Iout
Imax
= Iout
Settings
The procedure is described in principle in chapter 4.7.
!
The
UI
_
display and a related text
parameter appear in the setup
function window.
☞
Default setting after
RESET
(*
RST
):
OFF!
Figure 4.7.1 d
Path to Selection of the Pon Text Parameter
rnd – Rounding Off the Displayed Measured Value
Functions
•
Only effective for Uout and Iout measuring function
•
Number of decimal places which appear at the display
•
Stabilizes the display when fluctuation is expected at the last
decimal place of the measured value
Setting Parameter
☞
0: no rounding
☞
-1: Rounded off one decimal place
☞
-2: Rounded off two decimal places
Settings
The procedure is described in principle in chapter 4.7.
!
The
rnd
display and a related text
parameter appear in the setup function
window.
Figure 4.7.1 e
Path to Selection of the rnd Text Parameter
☞
Default setting after RESET (*
RST
):
unchanged
Select the text parameter
from an options loop
From the SEt function group
*
ENTER
CE/LOCAL
FUNCTION
Select the text parameter
from an options loop
From the SEt function group
*
ENTER
CE/LOCAL
FUNCTION