Technical Data

Nominal Output Frequency(Hz)

Max. Output  Current (A)

Output  Power Factor

Output  THDi (@Nomina Output)

50/60

50/60

50/60

50/60

50/60

5

7.5

10

12.5

13.5

~1(Adjustable from 0.8 leading to 0.8 lagging)

Europe efficiency

96.5%

97.0%

97.0%

97.5%

97.5%

97.0%

97.0%

Anti-islanding Protection

Input Reverse Polarity Protection

Insulation Resistor Detection

Residual Current Monitoring Unit

Output Over Current Protection

Output Short Protection

Output Over Voltage Protection

Operating Temperature Range(

)

Operating Altitude(m

)

User

 

Interface

Communication

Size Width

*

Height

*

Depth

 

mm

(

)

self

4000

al

LCD&LED

VDE0126-1-1,AS4777.2,EN50438(PL),G83,ERDF-NOI-RES_13E,IEC61727,IEC62116

EN 61000-6-1,EN 61000-6-2,EN 61000-6-3,EN 61000-6-4

3900

4680

5460

6500

Max.DC Input Power(W)

Max.DC Input voltage(V)

Start-up

MPPT Range for Full Load (V)

Nominal DC Input Voltage (V)

Max. Input Current (A)

Max. Short Current (A)

No.of MPP Trackers

No.of Input Strings per Tracker

PV String Input Data

Technical Data

Nominal Output Power (W)

Max. Output Apparent Power (VA)

Nominal Output Voltage (V)

150~450

180~450

210~450

250~450

360

11/11

360

360

360

13.8/13.8

2

1

1

1

1

220~230

220~230

220~230

220~230

Nominal Output Frequency(Hz)

Max. Output  Current (A)

Output  Power Factor

Output  THDi (@Nomina Output)

50/60

50/60

50/60

50/60

13.6

16

19

22.8

~1(Adjustable from 0.8 leading to 0.8 lagging)

Europe efficiency

97.8%

580

80~550

120

580

580

580

80~550

80~550

80~550

120

120

120

11/11

11/11

11/11

13.8/13.8

13.8/13.8

13.8/13.8

2

2

2

3000

3680

4200

5000

3000

3680

4200

5000

97.5%

AC overcurrent protection (A)

7

11

15

20

19

AC overvoltage category

Category III

Maximum output fault current a.c. A

(peak and duration)

0

Moisture location category

4K4H

Environment category

Outdoor

Indoor

External environment pollution degree

Grade1

2

 3

Nominal Output Power (W)

Max. Output Apparent Power (VA)

Nominal Output Voltage (V)

220~230

220~230

220~230

220~230

220~230

PV Over Current Protection(A)

DC overvoltage category

Category II

PV Backup Current(A)

0

AC overcurrent protection (A)

24

29

35

GW5KD-NS

6500

250~450

360

1

580

80~550

120

11/11

13.8/13.8

2

220~230

50/60

21.7

4600

4950

35

20

25/25

25/25

25/25

25/25

25/25

Output Inrush Current

(peak and duration)
AC Backfeed Current(A)

High Frequency Isolation

Integrated (AFD)

50A 100

μ

s

25A 5

μ

s

Technical Data

AC overvoltage category(A)
Maximum output fault current 

a.c. A(peak and duration)
Output Inrush Current

(peak and duration)

AC Backfeed Current(A)

Category III

0

50A 100

μ

s

25A 5

μ

s

Содержание GW-6000D-NS

Страница 1: ...om cn www goodwe com cn www goodwe com cn service au goodwe com cn GoodWe Australia www goodwe com cn service nl goodwe com cn GoodWe Netherlands GoodWe UK www goodwe co uk enquiries goodwe co uk Note The information above is subject to change without prior notice details refer to www goodwe com cn SOLAR INVERTER NS DNS SERIES USER MANUAL ...

Страница 2: ...nance 3 1 Mounting Instructions 3 2 Inverter Overview and Package 3 3 Inverter Installation 3 4 Electrical Connection 4 1 Indicator Lights 4 2 User Interface and Use of the Display 4 3 Error Code 4 4 WiFi Reset and Reload to Factory Setting 4 5 Special Adjustable Setpoints 01 02 02 03 05 13 13 16 17 01 17 18 22 17 22 ...

Страница 3: ...60 during operation To avoid being burnt do not touch the inverter during operation Let it cool before touching it Keep children away from inverter Do not open the front cover of the inverter Apart from performing work at the wiring terminal as instructed in this manual touching or changing components without authorization may cause injury to people damage to inverters and annulment of the warrant...

Страница 4: ... method must be appropriate for the inverter s weight and dimensions The location must be well ventilated and sheltered from direct sunlight The inverter must be installed vertical or with a backward tilt less than 15 No sideways tilt is allowed The connection area must point downwards Refer to Figure 3 3 1 1 To allow dissipation of heat and for convenience of dismantling clearances around the inv...

Страница 5: ...e are two AC connector brands for inverter VACONN and WIELAND Please refer to Figure 3 4 1 1 6 The AC line construction shall be such that if the cord should slip in its anchorage placing a strain on conductors the protective earthing conductor will be the last to take the strain such as the PE line is longger than L and N Installation instruction of VACONN series please refer to Figure 3 4 1 2 fa...

Страница 6: ... the detected leakage current exceeds the limit value inverter will quickly disconnect with the grid If the leakage current protection device is installed externally the action current should be 300mA or higher 3 4 3 DC Side Connection permanently damage the unit 2 The open circuit voltage of the PV strings cannot exceed the maximum input voltage of the inverter 3 Only DC connectors provided by us...

Страница 7: ...ication This function is only applied to inverters with RS485 The RS485 interface is used to connect EzLogger Pro and the maximum total length of all connecting cables should not exceed 800m RS485 connection is referred to 3 4 6 1 1 Connection Procedure Put the cable through the components in this order screw cap one hole sealing ring insulation body and sheet metal parts Take the green terminal o...

Страница 8: ...t not connected Connection Procedure Put the cable through the components in this order screw cap one hole sealing ring insulation body and sheet metal parts Pull out the 6 pin terminal from the socket in the cabinet and take off the resistor which is fixed in it Cable should be connected as Figure 3 4 8 2 Insert the green terminal into the corresponding interior terminal of the inverter Pull cabl...

Страница 9: ...it X X Set Power Limit XX Short press to select number 0 9 Short press to select number 0 9 Short press to select number 0 1 Long press 2S Long press 2S Long press 2S Long press 2S Or Set Modbus Addr Pac 2595 5W Short press Long press 2S Set Addr XXX Set Addr X X X Set Addr XXX Short press to select number 0 9 Short press to select number 0 2 Long press 2S Long press 2S Long press 2S Short press t...

Страница 10: ......

Страница 11: ...ite or contact with after sales PV Backfeed Current A 0 18 4 4 Wi Fi Reset Wi Fi Reload The two functions are only available for Wi Fi model inverters Wi Fi reload function is used to change the Wi Fi configuration to default value Please configure the Wi Fi again as 3 4 5 after using the function Press the key until the LCD displays Wi Fi Reset then long press 2S until the LCD displays Wi Fi Rese...

Страница 12: ... 220 230 220 230 220 230 220 230 Nominal Output Frequency Hz Max Output Current A Output Power Factor Output THDi Nomina Output 50 60 50 60 50 60 50 60 13 6 16 19 22 8 1 Adjustable from 0 8 leading to 0 8 lagging Europe efficiency 97 8 580 80 550 120 580 580 580 80 550 80 550 80 550 120 120 120 11 11 11 11 11 11 13 8 13 8 13 8 13 8 13 8 13 8 2 2 2 3000 3680 4200 5000 3000 3680 4200 5000 97 5 AC ov...

Страница 13: ...ly connected to the installation Examples are appliances portable tools and other plug connected equipment Category III applies to fixed equipment downstream of and including the main distribution board Examples are switchgear and other equipment in an industrial installation Category IV applies to equipment permanently connected at the origin of an installation upstream of the main distribution b...

Отзывы: