If there are more than 3 PV strings on input side, an additional fuse installing will be suggested.
An earthing photovoltaic system need to connect an Arc fault detector on DC side.
The inverter can exclude the possibility of DC residual currents to 6mA in the system,Where an external RCD is required
in addition to the built-in RCMU,  type A RCD must be used to avoid tripping

The PV- is not grounded as default configuration.

CE Mark

Signals danger due to electrical 

 

shock and indicates the time (5minutes) to allow after the 

inverter has been turned off and 

 

disconnected to ensure safety in any installation operation.

Caution! - Failure to observe a warning 
indicated in this manual may result in minor 
or moderate injury.

Danger of high voltage and electric shock!

Danger of hot surface!

Product should not be disposed as normal 
household waste.

Components of the product can be recycled.

This side up - The package must always be

 

transported, handled and stored in such a 
way that

 

the arrows always point upwards.

No more than six (6) identical packages be 
stacked on each other.

The package/product should be handled

 

carefully and never be tipped over or 
slung.

Keep Dry – The package/product must be 
protected from excessive humidity and 
must accordingly be stored under cover.

1 Symbols

2

  

Safety

 

The NS/DNS series inverter of Jiangsu GoodWe Power Supply Technology Co, Ltd. (hereinafter referred to as GoodWe) strictly

conforms to related safety rules in design and test. Safety regulations relevant to the location shall be followed during 

installation,

commissioning, operation and maintenance. Improper operation may have a risk of electric shock or damage to equipment 

and property. (NS: Single-MPPT,Single-Phase; DNS: Dual-MPPT,Single-Phase)

Installation, maintenance and connection of inverters must be performed by qualified personnel, in compliance with local 

electrical standards, regulations and the requirements of local power authorities and/or companies.

To avoid electric shock, DC input and AC output of the inverter must be disconnected and wait at least 5 minutes before 

performing any

 

installation or maintenance.

The temperature of some parts of the inverter may exceed 60

℃ 

during operation. To avoid being burnt, do not touch the 

inverter

 

during operation. Let it cool before touching it.

Keep children away from inverter.

Do not open the front cover of the inverter. Apart from performing work at the wiring terminal (as instructed in this manual),

touching or changing components without authorization may cause injury to people, damage to inverters and annulment of 

the

 

warranty.

Static electricity may damage electronic components. Appropriate method must be adopted to prevent such damage to the

inverter; otherwise the inverter may be damaged and the warranty annulled.

Ensure the output voltage of the proposed PV array is lover than the maximum rated input voltage of the inverter; otherwise 

the

 

inverter may be damaged and the warranty annulled.

When exposed to sunlight, the PV array generates dangerous high DC voltage. Please operate according to our instructions, 

or it

 

will result in danger to life.

PV modules should have an IEC61730 class A rating.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be

impaired.

Completely isolate the equipment should: switch off the DC switch, disconnect the DC terminal, and disconnect the AC 

terminal

 

or AC breaker.

Prohibit inserting or pulling the AC and DC terminals when the inverter is electrified.

3 Installation

3.1 Mounting Instruction

  

In order to achieve optimal performance, the ambient temperature should be lower than 45

.

   For the convenience of checking the LCD display and possible maintenance activities, please install the inverter at eye level.

   Inverters should NOT be installed near inflammable and explosive items. Any strong electro-magnetic equipment should be 

    

  

kept away from installation site.

   Product label and warning symbol shall be clear to read after installation.

   Please install inverter in the place where is not exposed to direct sunlight, rain and snow.

3.2 Inverter Overview and Package

Check the scope of delivery for completeness and any visible damage.

3.2.1 Inverter Overview

Appearance of NS Series 1-3KW refer to Figure3.2.1-1. Appearance of NS Series 3.6-5KW and DNS Series 3-5KW refer to Figure3.2.1-2.

2

1

3 4

5

6

7

8
9

1. PV input terminals
2. DC Switch (Optional)
3. RS485 port or USB port
4. WiFi BOX (Optional)
S. CT and DRED function
    (Optional)
6. AC output terminal
7. LCD display
8. Indicator lights
9. Button

Содержание GW-6000D-NS

Страница 1: ...om cn www goodwe com cn www goodwe com cn service au goodwe com cn GoodWe Australia www goodwe com cn service nl goodwe com cn GoodWe Netherlands GoodWe UK www goodwe co uk enquiries goodwe co uk Note The information above is subject to change without prior notice details refer to www goodwe com cn SOLAR INVERTER NS DNS SERIES USER MANUAL ...

Страница 2: ...nance 3 1 Mounting Instructions 3 2 Inverter Overview and Package 3 3 Inverter Installation 3 4 Electrical Connection 4 1 Indicator Lights 4 2 User Interface and Use of the Display 4 3 Error Code 4 4 WiFi Reset and Reload to Factory Setting 4 5 Special Adjustable Setpoints 01 02 02 03 05 13 13 16 17 01 17 18 22 17 22 ...

Страница 3: ...60 during operation To avoid being burnt do not touch the inverter during operation Let it cool before touching it Keep children away from inverter Do not open the front cover of the inverter Apart from performing work at the wiring terminal as instructed in this manual touching or changing components without authorization may cause injury to people damage to inverters and annulment of the warrant...

Страница 4: ... method must be appropriate for the inverter s weight and dimensions The location must be well ventilated and sheltered from direct sunlight The inverter must be installed vertical or with a backward tilt less than 15 No sideways tilt is allowed The connection area must point downwards Refer to Figure 3 3 1 1 To allow dissipation of heat and for convenience of dismantling clearances around the inv...

Страница 5: ...e are two AC connector brands for inverter VACONN and WIELAND Please refer to Figure 3 4 1 1 6 The AC line construction shall be such that if the cord should slip in its anchorage placing a strain on conductors the protective earthing conductor will be the last to take the strain such as the PE line is longger than L and N Installation instruction of VACONN series please refer to Figure 3 4 1 2 fa...

Страница 6: ... the detected leakage current exceeds the limit value inverter will quickly disconnect with the grid If the leakage current protection device is installed externally the action current should be 300mA or higher 3 4 3 DC Side Connection permanently damage the unit 2 The open circuit voltage of the PV strings cannot exceed the maximum input voltage of the inverter 3 Only DC connectors provided by us...

Страница 7: ...ication This function is only applied to inverters with RS485 The RS485 interface is used to connect EzLogger Pro and the maximum total length of all connecting cables should not exceed 800m RS485 connection is referred to 3 4 6 1 1 Connection Procedure Put the cable through the components in this order screw cap one hole sealing ring insulation body and sheet metal parts Take the green terminal o...

Страница 8: ...t not connected Connection Procedure Put the cable through the components in this order screw cap one hole sealing ring insulation body and sheet metal parts Pull out the 6 pin terminal from the socket in the cabinet and take off the resistor which is fixed in it Cable should be connected as Figure 3 4 8 2 Insert the green terminal into the corresponding interior terminal of the inverter Pull cabl...

Страница 9: ...it X X Set Power Limit XX Short press to select number 0 9 Short press to select number 0 9 Short press to select number 0 1 Long press 2S Long press 2S Long press 2S Long press 2S Or Set Modbus Addr Pac 2595 5W Short press Long press 2S Set Addr XXX Set Addr X X X Set Addr XXX Short press to select number 0 9 Short press to select number 0 2 Long press 2S Long press 2S Long press 2S Short press t...

Страница 10: ......

Страница 11: ...ite or contact with after sales PV Backfeed Current A 0 18 4 4 Wi Fi Reset Wi Fi Reload The two functions are only available for Wi Fi model inverters Wi Fi reload function is used to change the Wi Fi configuration to default value Please configure the Wi Fi again as 3 4 5 after using the function Press the key until the LCD displays Wi Fi Reset then long press 2S until the LCD displays Wi Fi Rese...

Страница 12: ... 220 230 220 230 220 230 220 230 Nominal Output Frequency Hz Max Output Current A Output Power Factor Output THDi Nomina Output 50 60 50 60 50 60 50 60 13 6 16 19 22 8 1 Adjustable from 0 8 leading to 0 8 lagging Europe efficiency 97 8 580 80 550 120 580 580 580 80 550 80 550 80 550 120 120 120 11 11 11 11 11 11 13 8 13 8 13 8 13 8 13 8 13 8 2 2 2 3000 3680 4200 5000 3000 3680 4200 5000 97 5 AC ov...

Страница 13: ...ly connected to the installation Examples are appliances portable tools and other plug connected equipment Category III applies to fixed equipment downstream of and including the main distribution board Examples are switchgear and other equipment in an industrial installation Category IV applies to equipment permanently connected at the origin of an installation upstream of the main distribution b...

Отзывы: