1300
1950
2600
3250
3900
Max.DC Input Power(W)
Max.DC Input voltage(V)
Start-up
MPPT Range for Full Load (V)
Nominal DC Input Voltage (V)
Max. Input Current (A)
Max. Short Current (A)
No.of MPP Trackers
No.of Input Strings per Tracker
PV String Input Data
Technical Data
120~450
180~450
230~450
180~450
215~450
360
10
360
360
360
360
10
10
18
18
12.5
1
1
PV Over Current Protection(A)
DC overvoltage category
Category II
20
4.5 Special Adjustable Setpoints
The inverter has field adjustable function,such as trip points,trip times, reconnect times,active and invalid of QU curve,PU curve.
It is adjustable through special software ,if you want to use it ,plaese contact with after sales.
The methods document of using the software can download from goodwe website or contact with after sales.
PV Backfeed Current(A)
0
18
4.4
Wi-Fi Reset & Wi-Fi Reload
The two functions are only available for Wi-Fi model inverters.
Wi-Fi reload function is used to change the Wi-Fi configuration to default value. Please configure the Wi-Fi again as 3.4.5 after using
the function.
Press the key until the LCD displays "Wi-Fi Reset", then long press (2S) until the LCD displays "Wi-Fi Resetting...". Stop pressing and
wait for the screen showing "Wi-Fi Reset OK" or "Wi-Fi Reset Failed".
Press the key until the LCD displays "Wi-Fi Reload", then long press (2S) until the LCD displays "Wi-Fi Reloading...". Stop pressing and
wait for the screen showing "Wi-Fi Reload OK" or "Wi-Fi Reload Failed".
Note: When sunlight is insufficient, the PV Inverter may continuously start up and shut down automatically due to insufficient
power generated by the PV panels, which would not lead to inverter damage. If the problem still exits, please call the local service