Figure 2.3.1-1

Figure 2.3.1-2

Figure 2.3.1-3

For inverter’s protection and convenient maintenance, mounting location for inverter should be 
selected carefully based on the following rules:
Any part of this system shouldn’t block the switch and breaker to disconnected inverter from DC and 
AC power.

Rule 1.

 Inverter should be installed on a solid surface, where is suitable for inverter’s dimensions and 

weight.

Rule 2.

 Inverter installation should stand vertically or lie on a slop by max 15° (Figure 2.3.1-1)

Rule 3.

 Ambient temperature should be lower than 45°C
 (High ambient temperature will cause power derating of inverter.)

Rule 4. 

The installation of inverter should be protected under shelter from direct sunlight or bad Rule 

weather like snow, rain, lightning etc. (Figure 2.3.1-2)

Rule 5. 

Inverter should be installed at eye level for convenient maintenance.

Rule 6.

 Product label on inverter should be clearly visible after installation.

Rule 7. 

Leave enough space around inverter following the values in Figure 2.3.1-3.

2.3 MOUNTING

2.3.1 SELECT MOUNTING LOCATION

2.1 UNACCEPTABLE INSTALLATIONS

 INSTALLATION INSTRUCTIONS

02

Pin Terminal × 12

User Manual × 1

Quick Installation

Guide × 1

2.2 PACKING LIST

BACK-UP CANNOT CONNECT IN PARALLEL.

ONE BATTERY BANK CANNOT BE CONNECT TO MULTIPLE 
INVERTERS.

INVERTER BATTERY INPUT CANNOT CONNECT TO 
INCOMPATIBLE BATTERIES.

BACK-UP SIDE CANNOT CONNECT TO GRID.

ON-GRID OR BACK-UP SIDE CANNOT CONNECT 
TO ANY AC GENERATOR.

ONE METER CANNOT CONNECT TO MULTIPE 
INVERTERS. AND DIFFERENT CT CANNOT CONNECT 
TO A SAME LINE CABLE.

300mm

500mm

200mm

200mm

300mm

Back-Up

Back-Up

Back-Up

On-Grid

Back-Up

On-Grid

Generator

Battery

Battery

Battery

Incompatible battery

Load

Upward
Downward
Front
Both sides

---------- 300mm

------ 500mm

------------- 300mm

-------- 200mm

Please avoid the following installations

which will damage the system or the Inverter.

On receiving the hybrid inverter, please check to make sure all the components as below are not missing 
or broken.

PE terminal × 1

Expansion bolts×4

AC Cover×1

Pan head screw×6

Smart Meter *1

with 3 CT

Positive BAT Plug×1

SmartMeter

Negative BAT Plug×1

Inverter×1

Wall-mounted

Bracket×1 

Inverter cannot be installed near flammable, explosive or strong electro-magnetic equipment.

[1]

06

05

BT QUICK INSTALLATION INSTRUCTIONS

PART 1

QUICK

INSTALLATION

PART 2

BATTERY

CONNECTION

PART 3

Wi-Fi

CONFIGURATION

UPS

Содержание BT Series

Страница 1: ...RETORFIT JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO LTD No 90 Zijin Rd New District Suzhou 215011 China www goodwe com service goodwe com 340 00330 00 PV Master APP SEMS Portal APP SEMS Portal website www semsportal com LinkedIn Company s offical website ...

Страница 2: ... 3 MOUNTING 2 3 1 SELECT MOUNTING LOCATION 2 3 2 MOUNTING 2 4 ELECTRICAL WIRING CONNECTION 2 4 1 BATTERY CONNECTION 2 4 2 ON GRID BACK UP CONNECTION 2 4 3 SMART METER CT CONNECTION 2 5 DRED EARTH FAULT ALARM 2 5 1 DRED CONNECTION 2 5 2 EARTH FAULT ALARM 3 1 WI FI CONFIGURATION WI FI RELOAD 3 2 GEI AUTO TEST INSTRUCTION 3 3 CEI AUTO TEST FUNCTION 4 1 ERROR MESSAGE AND TROUBLESHOOTING 4 2 DISCLAIMER...

Страница 3: ...f high voltage and electric shock Components of the product can be recycled This side up The package must always be transported handled and stored in such a way that the arrows always point upwards Danger of hot surface No more than six 6 identical packages being stacked on each other Product should not be disposed as household waste The package product should be handled carefully and never be tip...

Страница 4: ...ements of local grid authorities or companies like AS 4777 and AS NZS 3000 in Australia Prohibit to insert or pull the AC and DC terminals when the inverter is running Before any wiring connection or electrical operation on inverter all DC and AC power must be disconnected from inverter for at least 5 minutes to make sure inverter is totally isolated to avoid electric shock The temperature of inve...

Страница 5: ...ound inverter following the values in Figure 2 3 1 3 2 3 MOUNTING 2 3 1 SELECT MOUNTING LOCATION 2 1 UNACCEPTABLE INSTALLATIONS INSTALLATION INSTRUCTIONS 02 Pin Terminal 12 User Manual 1 Quick Installation Guide 1 2 2 PACKING LIST BACK UP CANNOT CONNECT IN PARALLEL ONE BATTERY BANK CANNOT BE CONNECT TO MULTIPLE INVERTERS INVERTER BATTERY INPUT CANNOT CONNECT TO INCOMPATIBLE BATTERIES BACK UP SIDE ...

Страница 6: ...battery to inverter and make sure inverter is totally isolated from AC power 4 Please following requirements and step bellow strictly Use improper wire may cause bad contact and high impedance which is dangerous to the system Please be careful against any electric shock or chemical hazard Make sure there is an external DC breaker 40A connected for battery without build in DC breaker The inverter i...

Страница 7: ...ut AC cable through terminal cover follow the sequence as on the right Figure 2 4 2 4 Note Please use the terminals in GoodWe components box Press the 10 connectors on cable conductor core tightly Figure 2 4 2 5 Note Make sure cable jacket is not locked within the connector 1 Connect the assembled AC cables into AC terminals with fastening torque about 2 0 2 5N m Note Connecting Back up terminals ...

Страница 8: ... contact GoodWe s after service Smart Meter CT Connection Diagram Figure 2 4 2 7 Smart Meter LED Indications Declaration For Back Up Overload Protection Inverer will restart itself as overload protection happens The preparation time for restarting will be longer and longer max one hour if overload protection repeats Take following steps to restart inverter immediately Decrease Back up load power w...

Страница 9: ...ing anti reverse function which could be different for different grid tied inverters Connection Diagram as below Figure 2 4 2 8 1 Put the cable through the plate as shown in Figure 2 5 1 4 2 Wiring from the No 5 and 6 holes respectively Connect DRED terminal to the right position onto the inverter Figure 2 5 1 5 Step 3 2 For Remote Shutdown Step 1 Step 2 Step 4 Screw this plate off from inverter F...

Страница 10: ... Depends on household loads 1 For batteries with attached breaker the external DC breaker could be omitted 2 Please use CT A for L1 CT B for L2 and CT C for L3 And follow House K Grid L direction to do the connection Otherwise there will be an error reminded by APP Battery To Battery AC Breaker DC Breaker AC Breaker AC Breaker Loads Grid PE N L3 L2 L1 To Smart Meter AC Breaker SmartMeter AC Breake...

Страница 11: ...ke the system work as customer needs 2 Monitor and check performance of the hybrid system 3 Wi Fi configuration Please download PV Master OPERATION INSTRUCTIONS from https en goodwe com Note 1 Please make sure the password Encryption Method Algorithm is right the same with the router s 2 If everything is right well the Wi Fi LED on inverter will change from double blink to quartic blink then to so...

Страница 12: ... inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter che...

Страница 13: ...al even not connect to router then please try to reload Wi Fi please refer to BT user manual page 17 Q Why cannot connect Solar WiFi signal on my phone A It is the character of the Wi Fi module that it can connect to only one device at a time If the signal is connected to another device at the time for some reason then you cannot connect to the signal About Battery Operation Q Why battery does not...

Страница 14: ... receive data from inverter or server normally it is because communica tion problem such as battery communication and communication between inverter and the APP About Smart Meter and Power Limit Function Q How to Act Output Power Limit function A For BT system the function could be realized by 1 Make sure Smart Meter connection and communication well 2 Turn on Export Power Limit function and set t...

Страница 15: ...ell please install the inverters in one day after unpacking otherwise please seal all unused terminals holes not allowed to keep any terminals holes open confirm there is no risk to have water dust in Maintemamce The inverter requires periodically maintenance details as below Make sure inverter is totally isolated from all DC and AC power for at least 5 mins before mainte nance Heat sink Please us...

Страница 16: ...nd other plug connected equipment Applies to a fixed equipment downstream and including the main distribution board Examples are switchgear and other euiquipment in an industrial installation Applies to equipment permanently connected at the origin of an installation uostream of the main distribution board Examples are electricity meters primary over current protection equipment and other equipmen...

Отзывы: