background image

MAMUAL OPERATION

03

10.10.100.253

Admin( U):

Password:

OK

CANCEL

Remember the password( R)

Device information

Firmware verison
MAC address
Wireless AP mode

SSID
IP address

Wireless STA mode

Router SSID
Encryption method
Encryption algorithm
Router Password

Start Setup

Cannot  join  the  network,  may  be  c aus ed  by:

router doesn't exist, or signal is too week, or password is incorrect

    Help: 

Wizard will help you to complete setting within one mimute.

1.6.9.3.38.2.1.38

60:C5:A8:60:33:E1

E nable

Solar-WiFi

10.10.100.253

Dis able

WiFi_Burn-in

WAP/WAP2-PSK

AES

WiFi_Burn-in

Add wireless network manually

Network name (SSID)
Encryption method
Encryption algorithm

Pleas e  enter  the  wireles s   network  pas s word:

Password (8-63 bytes)

show psk

Back

Next

W iF i-T es t

W PA/W PA2-PS K
AE S

hellogoodwe

      Note: 

case sensitive for SSID and password

  Please make sure all parameters of wireless network are matched with router,
including password

Step 1

Step 2

Step 3

Back

Complete

Confirm to complete?

If you still need to configure the other pages of information, please
go to complete your required configuration.

Click 'Complete', the current configuration will take effect after
restart.

Configuration is completed, you can log on the Management page
to restart device by Click on 'OK' button.

Save success!

Please select your current wireless network:

SSID

Sec mode

Enc type

Channel

RSSI

WIFI Test

WAP2-PSK

AES

6

54%

Back

Next

Note:

 When RSSI of the selected WiFi Network is lower than 10%, the

connection may be unstable, please select other available network or
shorten the distance between the device and the router.
If your wireless router does not broadcast SSID, please click "Next" and
add a wireless network manually.

3.2 PV MASTER APP OPERATION

PV Master is an external monitoring/ configuration application for 
GoodWe hybrid inverters, used on smart phones or pad for both 
Android and iOS system, main functions as below:
1. Edit system configuration to make the system work as customer 

needs.

2. Monitor and check performance of the hybrid system.
3. Wi-Fi configuration.

Please download PV Master OPERATION INSTRUCTIONS from 

https://en.goodwe.com/

Note:
1. Please make sure the password, Encryption Method/Algorithm is right the same with the router’s. 
2. If everything is right well, the Wi-Fi LED on inverter will change from double blink to quartic blink then to 

solid status, which means Wi-Fi is connected to GoodWe server successfully.

3. Wi-Fi configuration could also be done on PV Master, details please check on PV Master APP.

Note: Wi-Fi Reset & Reload function is only used when:
1. Wi-Fi lost connection to internet or cannot connect to PV Master APP successfully.
2. Cannot find “Solar-WiFi signal” or have other Wi-Fi configuration problem.
3. Please do not use this button if Wi-Fi monitoring works well.

3.3 CEI AUTO-TEST FUNCTION

PV Auto-Test function of CEI is integrated in PV Master APP for Italy safety country requirement. For 
detailed instruction of this function please reger to PV Master Operation Instructions.

Wi-Fi Reset

Wi-Fi Reload

short press Reset button
Wi-Fi Led will blink for a few seconds

long press Reset button (longer than 3s)
Wi-Fi Led will double blink until doing 
Wi-Fi configuration again.

3.1  WIFI CONFIGURATION

• This part shows configuration on web page.
• Wi-Fi configuration is absolutely necessary for online monitoring and after-sales maintenance.

PREPARATION:

1. Inverter must be powered up with Battery or grid power.
2. Need a router with available internet access to GoodWe portal 

https://www.semsportal.com

 

1. Connect Solar-WiFi* to your PC or smart 

phone(* means the last 8 characters of the 
inverter serial No.)

2. Open browser and login 10.10.100.253 

Admin (U): admin; Password: admin

3. Then click “OK”

1. Click “Start Setup” to choose your router
2. Then click “Next”

1. Fill in the password of the router, then 
click “Next”
2. Click “Complete”

•Wi-Fi Reset & Reload

Wi-Fi Reset means restarting Wi-Fi module, Wi-Fi settings will be reprocessed and saved automatically. 
Wi-Fi Reload means setting Wi-Fi module back to default factory setting.

18

17

Wi-Fi Reset Button

UPS

Wi-Fi

RESET

Содержание BT Series

Страница 1: ...RETORFIT JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO LTD No 90 Zijin Rd New District Suzhou 215011 China www goodwe com service goodwe com 340 00330 00 PV Master APP SEMS Portal APP SEMS Portal website www semsportal com LinkedIn Company s offical website ...

Страница 2: ... 3 MOUNTING 2 3 1 SELECT MOUNTING LOCATION 2 3 2 MOUNTING 2 4 ELECTRICAL WIRING CONNECTION 2 4 1 BATTERY CONNECTION 2 4 2 ON GRID BACK UP CONNECTION 2 4 3 SMART METER CT CONNECTION 2 5 DRED EARTH FAULT ALARM 2 5 1 DRED CONNECTION 2 5 2 EARTH FAULT ALARM 3 1 WI FI CONFIGURATION WI FI RELOAD 3 2 GEI AUTO TEST INSTRUCTION 3 3 CEI AUTO TEST FUNCTION 4 1 ERROR MESSAGE AND TROUBLESHOOTING 4 2 DISCLAIMER...

Страница 3: ...f high voltage and electric shock Components of the product can be recycled This side up The package must always be transported handled and stored in such a way that the arrows always point upwards Danger of hot surface No more than six 6 identical packages being stacked on each other Product should not be disposed as household waste The package product should be handled carefully and never be tip...

Страница 4: ...ements of local grid authorities or companies like AS 4777 and AS NZS 3000 in Australia Prohibit to insert or pull the AC and DC terminals when the inverter is running Before any wiring connection or electrical operation on inverter all DC and AC power must be disconnected from inverter for at least 5 minutes to make sure inverter is totally isolated to avoid electric shock The temperature of inve...

Страница 5: ...ound inverter following the values in Figure 2 3 1 3 2 3 MOUNTING 2 3 1 SELECT MOUNTING LOCATION 2 1 UNACCEPTABLE INSTALLATIONS INSTALLATION INSTRUCTIONS 02 Pin Terminal 12 User Manual 1 Quick Installation Guide 1 2 2 PACKING LIST BACK UP CANNOT CONNECT IN PARALLEL ONE BATTERY BANK CANNOT BE CONNECT TO MULTIPLE INVERTERS INVERTER BATTERY INPUT CANNOT CONNECT TO INCOMPATIBLE BATTERIES BACK UP SIDE ...

Страница 6: ...battery to inverter and make sure inverter is totally isolated from AC power 4 Please following requirements and step bellow strictly Use improper wire may cause bad contact and high impedance which is dangerous to the system Please be careful against any electric shock or chemical hazard Make sure there is an external DC breaker 40A connected for battery without build in DC breaker The inverter i...

Страница 7: ...ut AC cable through terminal cover follow the sequence as on the right Figure 2 4 2 4 Note Please use the terminals in GoodWe components box Press the 10 connectors on cable conductor core tightly Figure 2 4 2 5 Note Make sure cable jacket is not locked within the connector 1 Connect the assembled AC cables into AC terminals with fastening torque about 2 0 2 5N m Note Connecting Back up terminals ...

Страница 8: ... contact GoodWe s after service Smart Meter CT Connection Diagram Figure 2 4 2 7 Smart Meter LED Indications Declaration For Back Up Overload Protection Inverer will restart itself as overload protection happens The preparation time for restarting will be longer and longer max one hour if overload protection repeats Take following steps to restart inverter immediately Decrease Back up load power w...

Страница 9: ...ing anti reverse function which could be different for different grid tied inverters Connection Diagram as below Figure 2 4 2 8 1 Put the cable through the plate as shown in Figure 2 5 1 4 2 Wiring from the No 5 and 6 holes respectively Connect DRED terminal to the right position onto the inverter Figure 2 5 1 5 Step 3 2 For Remote Shutdown Step 1 Step 2 Step 4 Screw this plate off from inverter F...

Страница 10: ... Depends on household loads 1 For batteries with attached breaker the external DC breaker could be omitted 2 Please use CT A for L1 CT B for L2 and CT C for L3 And follow House K Grid L direction to do the connection Otherwise there will be an error reminded by APP Battery To Battery AC Breaker DC Breaker AC Breaker AC Breaker Loads Grid PE N L3 L2 L1 To Smart Meter AC Breaker SmartMeter AC Breake...

Страница 11: ...ke the system work as customer needs 2 Monitor and check performance of the hybrid system 3 Wi Fi configuration Please download PV Master OPERATION INSTRUCTIONS from https en goodwe com Note 1 Please make sure the password Encryption Method Algorithm is right the same with the router s 2 If everything is right well the Wi Fi LED on inverter will change from double blink to quartic blink then to so...

Страница 12: ... inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter che...

Страница 13: ...al even not connect to router then please try to reload Wi Fi please refer to BT user manual page 17 Q Why cannot connect Solar WiFi signal on my phone A It is the character of the Wi Fi module that it can connect to only one device at a time If the signal is connected to another device at the time for some reason then you cannot connect to the signal About Battery Operation Q Why battery does not...

Страница 14: ... receive data from inverter or server normally it is because communica tion problem such as battery communication and communication between inverter and the APP About Smart Meter and Power Limit Function Q How to Act Output Power Limit function A For BT system the function could be realized by 1 Make sure Smart Meter connection and communication well 2 Turn on Export Power Limit function and set t...

Страница 15: ...ell please install the inverters in one day after unpacking otherwise please seal all unused terminals holes not allowed to keep any terminals holes open confirm there is no risk to have water dust in Maintemamce The inverter requires periodically maintenance details as below Make sure inverter is totally isolated from all DC and AC power for at least 5 mins before mainte nance Heat sink Please us...

Страница 16: ...nd other plug connected equipment Applies to a fixed equipment downstream and including the main distribution board Examples are switchgear and other euiquipment in an industrial installation Applies to equipment permanently connected at the origin of an installation uostream of the main distribution board Examples are electricity meters primary over current protection equipment and other equipmen...

Отзывы: