About Wi-Fi Configuration

Q: Why cannot see Solar-WiFi* signal on mobile devices

A:  Normally Solar-WiFi* signal could be searched right after inverter powered up. But Solar-WiFi 

signal will disappear when BT connected to internet. If need to change settings, can connect to the 
router to change. If cannot see Wi-Fi signal even not connect to router, then please try to reload 
Wi-Fi (please refer to BT user manual page 17).

Q: Why cannot connect Solar-WiFi* signal on my phone?

A:  It is the character of the Wi-Fi module that it can connect to only one device at a time. If the signal 

is connected to another device at the time for some reason, then you cannot connect to the signal.

About Battery Operation

Q: Why battery does not discharge when grid is not available, while it discharges normally when 

grid is available?

A:  On APP, Off-Grid output and Back-Up function should be turned on to make battery discharge 

under Off-Grid mode.

Q: Why there is no output on Back-Up side?

A: For Back-Up supply, the “Back-Up Supply” on PV Master App must be turned on. Under Off-Grid 

mode or grid power is disconnected, “Off-Grid Output Switch” function must be turned on as well.

Note: As turn “Off-Grid Output Switch” on, don’t restart inverter or battery, otherwise the function will 

switch off automatically.

Q: On Portal, why battery SOC has a sudden jump up to 95%?

A: This normally happens on when BMS communication fail on lithium. If battery enter float charge, 

SOC will be reset to 95% compulsively.

Q: Why battery cannot be fully charged to 100%?

A:  Battery will stop charge when battery voltage reaches charge voltage set on PV Master APP.

Q: Why battery switch always trip when starts it up (Lithium battery)?

A: The switch of lithium battery normally trips for following reasons:
1. BMS communication fails.
2. Battery SOC is too low, battery trips to protect itself.
3. An electrical short-cut happened on battery connection side. Or other reasons please contact 

GoodWe for details.

Q: Which battery should I use for BT?

A: For BT series inverter, it could connect lithium batteries which have compatibility with BT series 

inverter with nominal voltage from 180V to 600V. Compatible lithium batteries can see on battery 
list in PV Master APP .

About PV Master Operation and Monitoring

Q: Why Cannot save settings on PV Master App

A: This could be caused by losing connection to Solar-WiFi *.

1. Make sure you connected Solar-WiFi* (make sure no other devices connected) or router (if 

connected Solar-WiFi* to router) and on APP home page shows connection well.

2. Make sure restart inverter 10mins later after you do some settings because inverter will save 

settings every 10 mins under normal mode. We recommend you change setting parameters 
when inverter under waiting mode.

Q: On the App, why the data on the homepage and Param page is different, like charge/dis-

charge, PV value, load value or grid value?

A: As the data on APP is from inverter and on home page and Param page, the data refresh frequency 

is different, so there will be a data inconformity between different pages on APP as well as between 
that on portal and APP .

Q: On App, some columns show NA, like battery SOH, etc. why is that?

A: NA means App does not receive data from inverter or server, normally it is because communica-

tion problem, such as battery communication, and communication between inverter and the APP.

About Smart Meter and Power Limit Function

Q: How to Act Output Power Limit function?

A: For BT system, the function could be realized by:

1. Make sure Smart Meter connection and communication well.
2. Turn on Export Power Limit function and set the max output power to grid on APP.

Note: If out-put power limit set as 0W,then there might still have deviation max 100W exporting to grid.

Q: Why there is still power exporting to grid after I set power limit as 0W?

A: Export limit could theoretically to minimum 0W, but there will have a deviation of around 50-100W 

for BT system.

Q: Can I use other brand Meter to take over Smart Meter in BT system or change some settings 

on Smart Meter?

A: No, because the communication protocol is inset between inverter and Smart Meter, other brand 

Meter cannot communicate. Also any manual setting change could cause Meter communication 
failure.

Q: What is the max current allowed going through CT on Smart Meter?

A: The max current for CT is 120A.

Other Questions

Q: Is there a quick way to make the system work?

A: The shortest way, please refer to BT QUICK INSTALLATION INSTRUCTIONS and PV MASTER 

APP INSTRUCTION.

Q: What kind of load can I connect on Back-Up side?

A: Please refer to user manual on page 12.

Q: Whether the warranty of the inverter still valid if the installation or operation does not follow 

the user manual instructions, for some special conditions when we cannot 100% follow them?

A: Normally if any problem caused by disobeys the instructions on user manual, we can provide 

technical support to help to solve the problem, but cannot guarantee a replacement or returns. So 
if there is any special conditions when you cannot 100% follow the instructions, please contact 
GoodWe for suggestions.

24

23

Содержание BT Series

Страница 1: ...RETORFIT JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO LTD No 90 Zijin Rd New District Suzhou 215011 China www goodwe com service goodwe com 340 00330 00 PV Master APP SEMS Portal APP SEMS Portal website www semsportal com LinkedIn Company s offical website ...

Страница 2: ... 3 MOUNTING 2 3 1 SELECT MOUNTING LOCATION 2 3 2 MOUNTING 2 4 ELECTRICAL WIRING CONNECTION 2 4 1 BATTERY CONNECTION 2 4 2 ON GRID BACK UP CONNECTION 2 4 3 SMART METER CT CONNECTION 2 5 DRED EARTH FAULT ALARM 2 5 1 DRED CONNECTION 2 5 2 EARTH FAULT ALARM 3 1 WI FI CONFIGURATION WI FI RELOAD 3 2 GEI AUTO TEST INSTRUCTION 3 3 CEI AUTO TEST FUNCTION 4 1 ERROR MESSAGE AND TROUBLESHOOTING 4 2 DISCLAIMER...

Страница 3: ...f high voltage and electric shock Components of the product can be recycled This side up The package must always be transported handled and stored in such a way that the arrows always point upwards Danger of hot surface No more than six 6 identical packages being stacked on each other Product should not be disposed as household waste The package product should be handled carefully and never be tip...

Страница 4: ...ements of local grid authorities or companies like AS 4777 and AS NZS 3000 in Australia Prohibit to insert or pull the AC and DC terminals when the inverter is running Before any wiring connection or electrical operation on inverter all DC and AC power must be disconnected from inverter for at least 5 minutes to make sure inverter is totally isolated to avoid electric shock The temperature of inve...

Страница 5: ...ound inverter following the values in Figure 2 3 1 3 2 3 MOUNTING 2 3 1 SELECT MOUNTING LOCATION 2 1 UNACCEPTABLE INSTALLATIONS INSTALLATION INSTRUCTIONS 02 Pin Terminal 12 User Manual 1 Quick Installation Guide 1 2 2 PACKING LIST BACK UP CANNOT CONNECT IN PARALLEL ONE BATTERY BANK CANNOT BE CONNECT TO MULTIPLE INVERTERS INVERTER BATTERY INPUT CANNOT CONNECT TO INCOMPATIBLE BATTERIES BACK UP SIDE ...

Страница 6: ...battery to inverter and make sure inverter is totally isolated from AC power 4 Please following requirements and step bellow strictly Use improper wire may cause bad contact and high impedance which is dangerous to the system Please be careful against any electric shock or chemical hazard Make sure there is an external DC breaker 40A connected for battery without build in DC breaker The inverter i...

Страница 7: ...ut AC cable through terminal cover follow the sequence as on the right Figure 2 4 2 4 Note Please use the terminals in GoodWe components box Press the 10 connectors on cable conductor core tightly Figure 2 4 2 5 Note Make sure cable jacket is not locked within the connector 1 Connect the assembled AC cables into AC terminals with fastening torque about 2 0 2 5N m Note Connecting Back up terminals ...

Страница 8: ... contact GoodWe s after service Smart Meter CT Connection Diagram Figure 2 4 2 7 Smart Meter LED Indications Declaration For Back Up Overload Protection Inverer will restart itself as overload protection happens The preparation time for restarting will be longer and longer max one hour if overload protection repeats Take following steps to restart inverter immediately Decrease Back up load power w...

Страница 9: ...ing anti reverse function which could be different for different grid tied inverters Connection Diagram as below Figure 2 4 2 8 1 Put the cable through the plate as shown in Figure 2 5 1 4 2 Wiring from the No 5 and 6 holes respectively Connect DRED terminal to the right position onto the inverter Figure 2 5 1 5 Step 3 2 For Remote Shutdown Step 1 Step 2 Step 4 Screw this plate off from inverter F...

Страница 10: ... Depends on household loads 1 For batteries with attached breaker the external DC breaker could be omitted 2 Please use CT A for L1 CT B for L2 and CT C for L3 And follow House K Grid L direction to do the connection Otherwise there will be an error reminded by APP Battery To Battery AC Breaker DC Breaker AC Breaker AC Breaker Loads Grid PE N L3 L2 L1 To Smart Meter AC Breaker SmartMeter AC Breake...

Страница 11: ...ke the system work as customer needs 2 Monitor and check performance of the hybrid system 3 Wi Fi configuration Please download PV Master OPERATION INSTRUCTIONS from https en goodwe com Note 1 Please make sure the password Encryption Method Algorithm is right the same with the router s 2 If everything is right well the Wi Fi LED on inverter will change from double blink to quartic blink then to so...

Страница 12: ... inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter che...

Страница 13: ...al even not connect to router then please try to reload Wi Fi please refer to BT user manual page 17 Q Why cannot connect Solar WiFi signal on my phone A It is the character of the Wi Fi module that it can connect to only one device at a time If the signal is connected to another device at the time for some reason then you cannot connect to the signal About Battery Operation Q Why battery does not...

Страница 14: ... receive data from inverter or server normally it is because communica tion problem such as battery communication and communication between inverter and the APP About Smart Meter and Power Limit Function Q How to Act Output Power Limit function A For BT system the function could be realized by 1 Make sure Smart Meter connection and communication well 2 Turn on Export Power Limit function and set t...

Страница 15: ...ell please install the inverters in one day after unpacking otherwise please seal all unused terminals holes not allowed to keep any terminals holes open confirm there is no risk to have water dust in Maintemamce The inverter requires periodically maintenance details as below Make sure inverter is totally isolated from all DC and AC power for at least 5 mins before mainte nance Heat sink Please us...

Страница 16: ...nd other plug connected equipment Applies to a fixed equipment downstream and including the main distribution board Examples are switchgear and other euiquipment in an industrial installation Applies to equipment permanently connected at the origin of an installation uostream of the main distribution board Examples are electricity meters primary over current protection equipment and other equipmen...

Отзывы: