SAFETY WARNING

1.3 PRODUCT OVERVIEW

HYBIRD LED INDICATORS

INDICATOR

SYSTEM

BACK-UP

BATTERY

GRID

ENERGY

COM

WiFi

FAULT

STATUS

ON = SYSTEM IS READY

BLINK =  SYSTEM IS STARTING UP

OFF = SYSTEM IS NOT OPERATING

ON = BACK-UP IS READY / POWER AVAILABLE

OFF = BACK-UP IS  OFF / ON POWER AVAILABLE

ON = BATTERY IS CHARGING

BLINK 1 = BATTERY IS DISCHARGING

BLINK 2 = BATTERY IS LOW / SOC IS LOW

OFF = BATTERY IS DISCONNECTED / NOT ACTIVE

ON = GRID IS ACTIVE AND CONNECTED

BLINK = GRID IS ACTIVE BUT NOT CONNECTED

OFF = GRID IS NOT ACTIVE

ON = CONSUMING ENERGY FROM GRID / BUYING

BLINK 1 = SUPPLYING ENERGY TO GRID / ZEROING

BLINK 2 = SUPPLYING ENERGY TO GRID / SELLING

OFF = GRID NOT CONNECTED OR SYSTEM NOT OPERATING

ON = BMS AND METER COMMUNICATION OK

OFF = BMS AND METER COMMUNICATION FAIL

ON = WiFi CONNECTED / ACTIVE

BLINK 1 = WiFi SYSTEM RESETTING

BLINK 2 = WiFi NOT CONNECT TO ROUTER

BLINK 4 = WiFi SERVER PROBLEM

OFF = WiFi NOT ACTIVE

ON = FAULT HAS OCCURRED

BLINK4 = CT WIRING FAULT

OFF  = NO FAULT 

 

EXPLANATION

SYSTEM

BACK-UP

BATTERY

GRID

ENERGY

COM

WiFi

FAULT

BLINK 1 = METER COMMUNICATION OK, 

BMS COMMUNICATION FAILI

BLINK 2 = BMS COMMUNICATION OK, 

METER COMMUNICATION FAIL

BLINK1 = OVERLOAD OF BACK-UP

OUTPUT / REDUCE LOAD

OFF

04

03

Any installation and operation on inverter must be performed by qualified electricians, in compliance 
with standards, wiring rules or requirements of local grid authorities or companies (like AS 4777 and 
AS/NZS 3000 in Australia).

Prohibit to insert or pull the AC and DC terminals when the inverter is running.

Before any wiring connection or electrical operation on inverter, all DC and AC power must be 
disconnected from inverter for at least 5 minutes to make sure inverter is totally isolated to avoid 
electric shock.

The temperature of inverter surface might exceed 60

 during working, so please make sure it 

is cooled down before touching it, and make sure the inverter is untouchable for children

Do not open inverter cover or change any components without GoodWe’s authorization, 
otherwise the warranty commitment for the inverter will be invalid.

Usage and operation of the inverter must follow instructions in this user manual, otherwise the 
protection design might be useless and warranty for the inverter will be invalid.

Appropriate methods must be adopted to protect inverter from static damage. Any damage 
caused by static is not warranted by GoodWe.

Battery negative(BAT-) on inveter side is not grounded as default design.
Connecting BAT- to EARTH are strictly forbidden.

The inverter, with built-in RCMU, will exclude possibility of DC residual current to 6mA, thus in 
the system an external RCD (type A) can be used(

30mA).

In Australia, the inverter internal switching does not maintain neutral integrity, which must be 
addressed by external connection arrangements like in the s Off-Grid System Connection 
Diagram in page 16.

In Australia, output of Back-Up side in switchbox should be labeled ‘Main switch UPS supply’, 
the output of normal load side in switch box should be labeled ‘main switch inverter supply’.

Содержание BT Series

Страница 1: ...RETORFIT JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO LTD No 90 Zijin Rd New District Suzhou 215011 China www goodwe com service goodwe com 340 00330 00 PV Master APP SEMS Portal APP SEMS Portal website www semsportal com LinkedIn Company s offical website ...

Страница 2: ... 3 MOUNTING 2 3 1 SELECT MOUNTING LOCATION 2 3 2 MOUNTING 2 4 ELECTRICAL WIRING CONNECTION 2 4 1 BATTERY CONNECTION 2 4 2 ON GRID BACK UP CONNECTION 2 4 3 SMART METER CT CONNECTION 2 5 DRED EARTH FAULT ALARM 2 5 1 DRED CONNECTION 2 5 2 EARTH FAULT ALARM 3 1 WI FI CONFIGURATION WI FI RELOAD 3 2 GEI AUTO TEST INSTRUCTION 3 3 CEI AUTO TEST FUNCTION 4 1 ERROR MESSAGE AND TROUBLESHOOTING 4 2 DISCLAIMER...

Страница 3: ...f high voltage and electric shock Components of the product can be recycled This side up The package must always be transported handled and stored in such a way that the arrows always point upwards Danger of hot surface No more than six 6 identical packages being stacked on each other Product should not be disposed as household waste The package product should be handled carefully and never be tip...

Страница 4: ...ements of local grid authorities or companies like AS 4777 and AS NZS 3000 in Australia Prohibit to insert or pull the AC and DC terminals when the inverter is running Before any wiring connection or electrical operation on inverter all DC and AC power must be disconnected from inverter for at least 5 minutes to make sure inverter is totally isolated to avoid electric shock The temperature of inve...

Страница 5: ...ound inverter following the values in Figure 2 3 1 3 2 3 MOUNTING 2 3 1 SELECT MOUNTING LOCATION 2 1 UNACCEPTABLE INSTALLATIONS INSTALLATION INSTRUCTIONS 02 Pin Terminal 12 User Manual 1 Quick Installation Guide 1 2 2 PACKING LIST BACK UP CANNOT CONNECT IN PARALLEL ONE BATTERY BANK CANNOT BE CONNECT TO MULTIPLE INVERTERS INVERTER BATTERY INPUT CANNOT CONNECT TO INCOMPATIBLE BATTERIES BACK UP SIDE ...

Страница 6: ...battery to inverter and make sure inverter is totally isolated from AC power 4 Please following requirements and step bellow strictly Use improper wire may cause bad contact and high impedance which is dangerous to the system Please be careful against any electric shock or chemical hazard Make sure there is an external DC breaker 40A connected for battery without build in DC breaker The inverter i...

Страница 7: ...ut AC cable through terminal cover follow the sequence as on the right Figure 2 4 2 4 Note Please use the terminals in GoodWe components box Press the 10 connectors on cable conductor core tightly Figure 2 4 2 5 Note Make sure cable jacket is not locked within the connector 1 Connect the assembled AC cables into AC terminals with fastening torque about 2 0 2 5N m Note Connecting Back up terminals ...

Страница 8: ... contact GoodWe s after service Smart Meter CT Connection Diagram Figure 2 4 2 7 Smart Meter LED Indications Declaration For Back Up Overload Protection Inverer will restart itself as overload protection happens The preparation time for restarting will be longer and longer max one hour if overload protection repeats Take following steps to restart inverter immediately Decrease Back up load power w...

Страница 9: ...ing anti reverse function which could be different for different grid tied inverters Connection Diagram as below Figure 2 4 2 8 1 Put the cable through the plate as shown in Figure 2 5 1 4 2 Wiring from the No 5 and 6 holes respectively Connect DRED terminal to the right position onto the inverter Figure 2 5 1 5 Step 3 2 For Remote Shutdown Step 1 Step 2 Step 4 Screw this plate off from inverter F...

Страница 10: ... Depends on household loads 1 For batteries with attached breaker the external DC breaker could be omitted 2 Please use CT A for L1 CT B for L2 and CT C for L3 And follow House K Grid L direction to do the connection Otherwise there will be an error reminded by APP Battery To Battery AC Breaker DC Breaker AC Breaker AC Breaker Loads Grid PE N L3 L2 L1 To Smart Meter AC Breaker SmartMeter AC Breake...

Страница 11: ...ke the system work as customer needs 2 Monitor and check performance of the hybrid system 3 Wi Fi configuration Please download PV Master OPERATION INSTRUCTIONS from https en goodwe com Note 1 Please make sure the password Encryption Method Algorithm is right the same with the router s 2 If everything is right well the Wi Fi LED on inverter will change from double blink to quartic blink then to so...

Страница 12: ... inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter che...

Страница 13: ...al even not connect to router then please try to reload Wi Fi please refer to BT user manual page 17 Q Why cannot connect Solar WiFi signal on my phone A It is the character of the Wi Fi module that it can connect to only one device at a time If the signal is connected to another device at the time for some reason then you cannot connect to the signal About Battery Operation Q Why battery does not...

Страница 14: ... receive data from inverter or server normally it is because communica tion problem such as battery communication and communication between inverter and the APP About Smart Meter and Power Limit Function Q How to Act Output Power Limit function A For BT system the function could be realized by 1 Make sure Smart Meter connection and communication well 2 Turn on Export Power Limit function and set t...

Страница 15: ...ell please install the inverters in one day after unpacking otherwise please seal all unused terminals holes not allowed to keep any terminals holes open confirm there is no risk to have water dust in Maintemamce The inverter requires periodically maintenance details as below Make sure inverter is totally isolated from all DC and AC power for at least 5 mins before mainte nance Heat sink Please us...

Страница 16: ...nd other plug connected equipment Applies to a fixed equipment downstream and including the main distribution board Examples are switchgear and other euiquipment in an industrial installation Applies to equipment permanently connected at the origin of an installation uostream of the main distribution board Examples are electricity meters primary over current protection equipment and other equipmen...

Отзывы: