4.3 TECHNICAL PARAMETERS AND CERTIFICATES

• TECHNICAL PARAMETERS OF BT INVERTERS

GW5K-BT

5000
5500

10000

8.5

15.2

5000

10000, 60sec

8.5

GW6K-BT

6000
6600

12000

10.5
18.2

6000

12000, 60sec

10.5

GW8K-BT

8000
8800

15000

13.5
22.7

8000

15000, 60sec

13.5

GW10K-BT

10000
11000
15000

16.5
22.7

10000

15000, 60sec

16.5

* According to the local grid regulation
** Can be reached only if battery capacity is enough, otherwise will shut down.
*** CAN communication is configured by default. If 485 communication is used, please replace the corresponding communication line. 
**** No Back-up Output

-35~60
0~95%

≤4000

Nature Convection

<30

LED & APP

RS485; CAN(***)

RS485

RS485 (Insulated)

Wi-Fi;LAN

21

516*415*180

Wall Bracket

IP65

<15

Transformerless

CEI 0-21; VDE-AR-N 4105; G98/1; G100; EN 50438

IEC/EN 62477

EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4, 

EN61000-4-16, EN61000-4-18, EN61000-4-29

4.2 DISCLAIMER

The BT series inverters are transported, used and operated under environmental and electrical 
conditions. GoodWe has the right not providing after-sales services or assistance under following 
conditions:
• Inverter is damaged during transferring.
• Inverter is out of warranty year and extended warranty is not bought.
• Inverter is installed, refitted or operated in improper ways without authority from GoodWe.
• Inverter is installed or used under improper environment or technical condition mentioned in this 

user manual, without authority from GoodWe.

• Installation or configuration of the inverter does not follow requirements mentioned in this user 

manual.

• The inverter is installed or operated against the requirements or warnings that are mentioned in this 

user manual.

• Inverter is broken or damaged by any force majeure like lightening, earthquake, fire hazard, storm 

and volcanic eruption etc.

• Inverter is disassembled, changed or updated on software or hardware without authority from 

GoodWe.

• Inverter is installed, used or operated against any related items in international or local policies or 

regulations.

• Any non-compatible batteries, loads or other devices connected to BT system.

Note: GoodWe will keep right to explain all the contents in this user manual. To insure IP65, inverter must 

be sealed well, please install the inverters in one day after unpacking, otherwise please seal all 
unused terminals/holes, not allowed to keep any terminals/holes open, confirm there is no risk to 
have water & dust in.

Maintemamce

The inverter requires periodically maintenance, details as below:
• Make sure inverter is totally isolated from all DC and AC power for at least 5 mins before mainte-

nance.

• Heat sink: Please use clean towel to clean up heat sink once a year.
• Torque: Please use torque wrench to tighten AC and DC wiring connection once a year.
• DC breaker: Check DC breaker regularly, active the DC breaker 10 times in a row once a year.
• Operating DC breaker will clean contacts and extend lifespan of DC breaker.
• Water-proof covers: Check if water-proof covers of RS485 and other part are replaced once a year.

Li-Ion

180~600

25
25

Self-adaption to BMS

400/380, 3L/N/PE

50/60

~1 (Adjustable from 0.8 leading to 0.8 lagging)

<3%

400/380

50/60

<3%

97.6%
97.6%

Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated

26

25

Technical Data

Battery Input Data

Battery Type
Battery Voltage Range (V)
Max. Charging Current (A)
Max. Discharging Current (A)
Charging Strategy for Li-Ion Battery

AC Output Data (On-grid)

Nominal Apparent Power Output to Utility Grid (VA)
Max. Apparent Power Output to Utility Grid (VA) *
Max. Apparent Power from Utility Grid (VA)
Nominal Output Voltage (V)
Nominal Output frequency (Hz)
Max. AC Current Output to Utility Grid (A)
Max. AC Current From Utility Grid (A)
Output Power Factor 
Output THDi  (@Nominal Output)

AC Output Data (Back-up)

Max. Output Apparent Power (VA)
Peak Output Apparent Power (VA) **
Max. Output Current (A)
Nominal Output Voltage (V)
Nominal Output Frequency (Hz)
Output THDv (@Linear Load)

Efficiency 

Max. Battery to Load Efficiency
Max. Charge Efficiency

Protection

Anti-islanding Protection
Insulation Resistor Detection
Residual Current Monitoring Unit
Output Over Current Protection
Output Short Protection
Battery Input Reverse Polarity Protection
Output Over Voltage Protection

General Data

Operating Temperature Range (

)

Relative Humidity
Operating Altitude (m

Cooling 
Noise (dB)
User Interface
Communication with BMS 
Communication with Meter
Communication with EMS
Communication with Portal
Weight (kg)
Size (Width*Height*Depth mm

Mounting
Protection Degree
Standby Self Consumption (W) ****
Topology

Certifications & Standards

Grid Regulation
Safety Regulation
EMC

Содержание BT Series

Страница 1: ...RETORFIT JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO LTD No 90 Zijin Rd New District Suzhou 215011 China www goodwe com service goodwe com 340 00330 00 PV Master APP SEMS Portal APP SEMS Portal website www semsportal com LinkedIn Company s offical website ...

Страница 2: ... 3 MOUNTING 2 3 1 SELECT MOUNTING LOCATION 2 3 2 MOUNTING 2 4 ELECTRICAL WIRING CONNECTION 2 4 1 BATTERY CONNECTION 2 4 2 ON GRID BACK UP CONNECTION 2 4 3 SMART METER CT CONNECTION 2 5 DRED EARTH FAULT ALARM 2 5 1 DRED CONNECTION 2 5 2 EARTH FAULT ALARM 3 1 WI FI CONFIGURATION WI FI RELOAD 3 2 GEI AUTO TEST INSTRUCTION 3 3 CEI AUTO TEST FUNCTION 4 1 ERROR MESSAGE AND TROUBLESHOOTING 4 2 DISCLAIMER...

Страница 3: ...f high voltage and electric shock Components of the product can be recycled This side up The package must always be transported handled and stored in such a way that the arrows always point upwards Danger of hot surface No more than six 6 identical packages being stacked on each other Product should not be disposed as household waste The package product should be handled carefully and never be tip...

Страница 4: ...ements of local grid authorities or companies like AS 4777 and AS NZS 3000 in Australia Prohibit to insert or pull the AC and DC terminals when the inverter is running Before any wiring connection or electrical operation on inverter all DC and AC power must be disconnected from inverter for at least 5 minutes to make sure inverter is totally isolated to avoid electric shock The temperature of inve...

Страница 5: ...ound inverter following the values in Figure 2 3 1 3 2 3 MOUNTING 2 3 1 SELECT MOUNTING LOCATION 2 1 UNACCEPTABLE INSTALLATIONS INSTALLATION INSTRUCTIONS 02 Pin Terminal 12 User Manual 1 Quick Installation Guide 1 2 2 PACKING LIST BACK UP CANNOT CONNECT IN PARALLEL ONE BATTERY BANK CANNOT BE CONNECT TO MULTIPLE INVERTERS INVERTER BATTERY INPUT CANNOT CONNECT TO INCOMPATIBLE BATTERIES BACK UP SIDE ...

Страница 6: ...battery to inverter and make sure inverter is totally isolated from AC power 4 Please following requirements and step bellow strictly Use improper wire may cause bad contact and high impedance which is dangerous to the system Please be careful against any electric shock or chemical hazard Make sure there is an external DC breaker 40A connected for battery without build in DC breaker The inverter i...

Страница 7: ...ut AC cable through terminal cover follow the sequence as on the right Figure 2 4 2 4 Note Please use the terminals in GoodWe components box Press the 10 connectors on cable conductor core tightly Figure 2 4 2 5 Note Make sure cable jacket is not locked within the connector 1 Connect the assembled AC cables into AC terminals with fastening torque about 2 0 2 5N m Note Connecting Back up terminals ...

Страница 8: ... contact GoodWe s after service Smart Meter CT Connection Diagram Figure 2 4 2 7 Smart Meter LED Indications Declaration For Back Up Overload Protection Inverer will restart itself as overload protection happens The preparation time for restarting will be longer and longer max one hour if overload protection repeats Take following steps to restart inverter immediately Decrease Back up load power w...

Страница 9: ...ing anti reverse function which could be different for different grid tied inverters Connection Diagram as below Figure 2 4 2 8 1 Put the cable through the plate as shown in Figure 2 5 1 4 2 Wiring from the No 5 and 6 holes respectively Connect DRED terminal to the right position onto the inverter Figure 2 5 1 5 Step 3 2 For Remote Shutdown Step 1 Step 2 Step 4 Screw this plate off from inverter F...

Страница 10: ... Depends on household loads 1 For batteries with attached breaker the external DC breaker could be omitted 2 Please use CT A for L1 CT B for L2 and CT C for L3 And follow House K Grid L direction to do the connection Otherwise there will be an error reminded by APP Battery To Battery AC Breaker DC Breaker AC Breaker AC Breaker Loads Grid PE N L3 L2 L1 To Smart Meter AC Breaker SmartMeter AC Breake...

Страница 11: ...ke the system work as customer needs 2 Monitor and check performance of the hybrid system 3 Wi Fi configuration Please download PV Master OPERATION INSTRUCTIONS from https en goodwe com Note 1 Please make sure the password Encryption Method Algorithm is right the same with the router s 2 If everything is right well the Wi Fi LED on inverter will change from double blink to quartic blink then to so...

Страница 12: ... inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter check if it still happens If not it is just an occasional situation Otherwise contact GoodWe immediately Try to restart inverter che...

Страница 13: ...al even not connect to router then please try to reload Wi Fi please refer to BT user manual page 17 Q Why cannot connect Solar WiFi signal on my phone A It is the character of the Wi Fi module that it can connect to only one device at a time If the signal is connected to another device at the time for some reason then you cannot connect to the signal About Battery Operation Q Why battery does not...

Страница 14: ... receive data from inverter or server normally it is because communica tion problem such as battery communication and communication between inverter and the APP About Smart Meter and Power Limit Function Q How to Act Output Power Limit function A For BT system the function could be realized by 1 Make sure Smart Meter connection and communication well 2 Turn on Export Power Limit function and set t...

Страница 15: ...ell please install the inverters in one day after unpacking otherwise please seal all unused terminals holes not allowed to keep any terminals holes open confirm there is no risk to have water dust in Maintemamce The inverter requires periodically maintenance details as below Make sure inverter is totally isolated from all DC and AC power for at least 5 mins before mainte nance Heat sink Please us...

Страница 16: ...nd other plug connected equipment Applies to a fixed equipment downstream and including the main distribution board Examples are switchgear and other euiquipment in an industrial installation Applies to equipment permanently connected at the origin of an installation uostream of the main distribution board Examples are electricity meters primary over current protection equipment and other equipmen...

Отзывы: