background image

2

Filters ........................................................ 6

PIPING ........................................................ 6

Condensate Drain ......................................... 6

WIRING ....................................................... 6

High Voltage Wiring ...................................... 7
Low Voltage Wiring ....................................... 7
Internal Wiring: ........................................... 7

OPERATION .................................................. 7

Start-Up Procedure and Checklist .................... 7
Heat Pump Start-Up Procedure ....................... 8
Final System Checks ...................................... 8

COMPONENTS ...............................................

9

Contactor.................................................... 9
Crankcase Heater ......................................... 9
Condenser Motor .......................................... 9
Compressor ................................................. 9
Contactor Relay ............................................ 9
Defrost Control ............................................ 9
Outdoor Thermostat ...................................... 9
Reversing Valve Coil ...................................... 9
Indoor Blower Motor ...................................... 9
Blower Interlock Relay ................................... 9

EXPLANATION AND GUIDANCE (HEAT PUMP) .......... 9

DEFROST CONTROL ....................................... 10

SUGGESTED FIELD TESTINGN/TROUBLESHOOTING .. 10

AIR FLOW MEASUREMENT AND ADJUSTMENT ......... 10

ADJUSTING SPEED TAP FOR INDOOR
BLOWER MOTOR ........................................... 10

EXPANSION VALVE (TXV) SYSTEM

SINGLE SPEED APPLICATION
(GPH1624-42) ..........................................

11

TWO SPEED APPLICATION (GPH1648 / GPC1560) .. 12

ELECTRIC HEAT INSTALLATION & ADJUSTMENT ...... 12

MAINTENANCE ............................................. 13

SERVICE ..................................................... 13

Inadequate Air Volume Through Indoor Coil .......13
Outside Air Into Return Duct ..........................13
Undercharge ..............................................13
Poor “Terminating” Sensor Contact .................13
Malfunctioning Reversing Valve ......................13

BLOWER PERFORMANCE  GP* 15/16 SEER ....... 14-15

TROUBLESHOOTING CHART.............................. 16

START-UP CHECKLIST ..................................... 18

O

NLY

 

PERSONNEL

 

THAT

 

HAVE

 

BEEN

 

TRAINED

 

TO

 

INSTALL

ADJUST

SERVICE

 

OR

 

REPAIR

 (

HEREINAFTER

, “

SERVICE

”) 

THE

 

EQUIPMENT

 

IN

 

THIS

 

MANUAL

 

SHOULD

 

SERVICE

 

THE

 

EQUIPMENT

. I

N

 

ADDITION

IN

 

JURISDICTIONS

 

THAT

 

REQUIRE

 

ONE

 

OR

 

MORE

 

LICENSES

 

TO

 

SERVICE

 

THE

 

EQUIPMENT

 

SPECIFIED

 

IN

 

THIS

 

MANUAL

ONLY

 

LICENSED

 

PERSONNEL

 

SHOULD

 

SERVICE

 

THE

 

EQUIPMENT

.  I

MPROPER

 

INSTALLATION

ADJUSTMENT

SERVICING

 

OR

 

REPAIR

 

OF

 

THE

 

EQUIPMENT

 

SPECIFIED

 

IN

 

THIS

 

MANUAL

OR

 

ATTEMPTING

 

TO

 

INSTALL

ADJUST

SERVICE

 

OR

 

REPAIR

 

THE

 

EQUIPMENT

 

SPECIFIED

 

IN

 

THIS

 

MANUAL

 

WITHOUT

 

PROPER

 

TRAINING

 

MAY

 

RESULT

 

IN

 

PRODUCT

 

DAMAGE

PROPERTY

 

DAMAGE

PERSONAL

 

INJURY

 

OR

 

DEATH

.

\

TO

THE INSTALLER

Carefully read all instructions for the installation prior to
installing unit. Make sure each step or procedure is under-
stood and any special considerations are taken into account
before starting installation.  Assemble all tools, hardware
and supplies needed to complete the installation. Some items
may need to be purchased locally. After deciding where to
install unit, closely look the location over - both the inside
and outside of home. Note any potential obstacles or prob-
lems that might be encountered as noted in this manual.
Choose a more suitable location if necessary.

IMPORTANT NOTE:

   If a crankcase heater is used, the unit

should be energized 24 hours prior to compressor start up to
ensure crankcase heater has sufficiently warmed the com-
pressor.  Compressor damage may occur if this step is not
followed.

Before using this manual, check the serial plate for proper
model identification.

The installation and servicing of this equipment must be
performed by qualified, experienced technicians only.

TO THE INSTALLER ........................................... 2

SHIPPING INSPECTION .................................... 2

Checking Product Received ............................ 2
Message to the Homeowner ............................. 3

REPLACEMENT PARTS ...................................... 3

Ordering Parts ............................................. 3

IMPORTANT SAFETY INSTRUCTIONS .................... 3

Recognize Safety Symbols, Words, and Labels .... 3

CODES AND REGULATIONS ................................ 3

General ...................................................... 3
EPA Regulations ............................................ 4
National Codes ............................................. 4

MAJOR COMPONENTS...................................... 4

General ...................................................... 4

INSTALLATION ............................................... 4

Pre-Installation Checkpoints ........................... 4
Clearance ................................................... 4
Location ..................................................... 4
Outside Slab Installation ................................ 4
Rooftop Installation ....................................... 5

DUCTING ..................................................... 5

Connecting the Return and Supply Flexible Duct
in Manufactured or
Modular Housing Application ........................... 5
Plenum Application ....................................... 6

Содержание GPC15 SEER

Страница 1: ...licable to your model for information regarding accessories NOTE Please contact your distributor or our website for the applicable Specifications Sheets referred to in this manual IMPORTANT This produ...

Страница 2: ...MENT SPECIFIED IN THIS MANUAL WITHOUT PROPER TRAINING MAY RESULT IN PRODUCT DAMAGE PROPERTY DAMAGE PERSONAL INJURY OR DEATH T O THE INSTALLER Carefully read all instructions for the installation prior...

Страница 3: ...Failure to heed safety information increases the risk of serious personal injury or death property damage and or product damage WARNING TO AVOID PROPERTY DAMAGE PERSONAL INJURY OR DEATH DO NOT USE THI...

Страница 4: ...EASE CONTACT THE LOCAL OFFICE OF THE EPA National Codes This product is designed and manufactured to permit installation in accordance with National Codes It is the installer s responsibility to insta...

Страница 5: ...k should be fabricated by the installing contractor in accordance with local codes Industry manuals may be used as a guide when sizing and designing the duct system such as NESCA National Environmenta...

Страница 6: ...ded for easy and convenient access to the filters for periodic inspection and cleaning Filters must have adequate face area for the rated quantity of the unit See air delivery tables Figure 4 for reco...

Страница 7: ...unit is located on the electrical box cover If any of the original wire supplied with the appliance must be replaced the wire gauge and insulation must be the same as the original wiring Transformer...

Страница 8: ...day when conditions are more suitable but DO NOT FAIL TO TEST If the out door ambient is low and the unit operates properly on the heating cycle you may check the pressure cutout operation by blockin...

Страница 9: ...used to prevent full electric heater operation at varying outdoor ambient 0 F to 45 F They are normally open above their set points and closed below to permit staging of indoor supplement heater oper...

Страница 10: ...unit s defrost period SUGGESTED FIELD TESTING TROUBLESHOOTING 1 Run unit in the heating mode room thermostat calling for heat 2 Check unit for proper charge Note Bands of frost on the condenser coil i...

Страница 11: ...on Temperature from tables or pressure gauge saturated temperature scale R 410A 2 Read suction line temperature 3 Use the following formula SUPERHEAT SUCTION LINE TEMP SAT SUCTION TEMP EXPANSION VALVE...

Страница 12: ...tion for the specific installation Permanently mark the unit s nameplate with the model being installed High and low voltage connections are detailed in the heat kit instructions Indoor Blower motor s...

Страница 13: ...tubing Poor contact may not terminate the unit s defrost cycle quickly enough to prevent the unit from cutting out on high discharge pressure Malfunctioning Reversing Valve This may be due to 1 Soleno...

Страница 14: ...09 122 134 147 159 172 184 CFM 1123 1068 1014 959 905 850 796 741 Watts 123 136 148 161 173 186 198 211 CFM 1462 1409 1357 1305 1252 1200 1147 1095 Watts 241 253 266 278 291 303 315 328 CFM 1005 961 9...

Страница 15: ...767 1732 1669 1618 Watts 498 521 516 534 385 567 571 574 CFM 1130 1080 1020 968 993 887 826 762 Watts 125 139 150 161 175 186 190 207 CFM 1712 1655 1587 1541 1486 1444 1393 1340 Watts 337 348 358 375...

Страница 16: ...ssor stuck grounded or open winding open internal overload b Wait at least 2 hours for overload to reset If still open replace the compressor c Low voltage connection c At compressor terminals voltage...

Страница 17: ...evaporator coil The safest way to clean the evaporator coil is to sim ply flush the coil with water This cleaning practice remains as the recommended cleaning method for both copper tube and aluminum...

Страница 18: ...ance around the unit for safety service maintenance and proper unit operation Verify proper weatherproofing of all ductwork roof curbs and electrical connections Check that the flue screen is in place...

Страница 19: ...t 1 Compressor Amps Circuit 2 Compressor Amps Blower Amps Condenser Fan Amps ELECTRICAL Total External Static Pressure Blower Wheel RPM TEMPERATURES Outdoor Air Temperature Return Air Temperature Cool...

Страница 20: ...20 Goodman Manufacturing Company L P 5151 San Felipe Suite 500 Houston TX 77056 www goodmanmfg com 2015 2016 Goodman Manufacturing Company L P...