background image

24

R

EPLACE

 

OR

 C

LEAN

 F

ILTER

IMPORTANT NOTE: 

Never operate unit without a filter installed

as dust and lint will build up on internal parts resulting in loss
of efficiency, equipment damage and possible fire.

An indoor air filter must be used with your comfort system. A
properly maintained filter will keep the indoor coil of your com-
fort system clean. A dirty coil could cause poor operation and/
or severe equipment damage.

Your air filter or filters could be located in your furnace, in a
blower unit, or in “filter grilles” in your ceiling or walls. The
installer of your air conditioner or heat pump can tell you where
your filter(s) are, and how to clean or replace them.

Check your filter(s) at least once a month. When they are
dirty, replace or clean as required. Disposable type filters should
be replaced. Reusable type filters may be cleaned.

You may want to ask your dealer about high efficiency filters.
High efficiency filters are available in both electronic and non-
electronic types. These filters can do a better job of catching
small airborne particles.

C

OMPRESSOR

The compressor motor is hermetically sealed and does not
require additional oiling.

M

OTORS

Indoor and outdoor fan motors are permanently lubricated and
do not require additional oiling.

C

LEAN

 O

UTSIDE

 C

OIL

 (Q

UALIFIED

 S

ERVICER

 O

NLY

)

Air must be able to flow through the outdoor unit of your com-
fort system. Do not construct a fence near the unit or build a
deck or patio over the unit without first discussing your plans
with your  dealer or other qualified servicer. Restricted airflow
could lead to poor operation and/or severe equipment damage.

Likewise, it is important to keep the outdoor coil clean. Dirt,
leaves, or debris could also restrict the airflow. If cleaning of
the outdoor coil becomes necessary, hire a qualified servicer.
Inexperienced people could easily puncture the tubing in the
coil. Even a small hole in the tubing could eventually cause a
large loss of refrigerant. Loss of refrigerant can cause poor
operation and/or severe equipment damage.

Do not use a condensing unit cover to “protect” the outdoor
unit during the winter, unless you first discuss it with your  dealer.
Any cover used must include “breathable” fabric to avoid mois-
ture buildup.

Check the thermostat to confirm that it is properly set.

Wait 15 minutes. Some devices in the outdoor unit or in
programmable thermostats will prevent compressor
operation for awhile, and then reset automatically. Also,
some power companies will install devices which shut
off air conditioners for several minutes on hot days. If
you wait several minutes, the unit may begin operation
on its own.

T

O

 

AVOID

 

THE

 

RISK

 

OF

 

EQUIPMENT

 

DAMAGE

 

OR

 

FIRE

INSTALL

THE

 

SAME

 

AMPERAGE

 

BREAKER

 

OR

 

FUSE

 

AS

 

YOU

 

ARE

REPLACING

.  I

F

 

THE

 

CIRCUIT

 

BREAKER

 

OR

 

FUSE

 

SHOULD

 

OPEN

AGAIN

 

WITHIN

 

THIRTY

 

DAYS

CONTACT

 

A

 

QUALIFIED

 

SERVICER

TO

 

CORRECT

 

THE

 

PROBLEM

.

I

F

 

YOU

 

REPEATEDLY

 

RESET

 

THE

 

BREAKER

 

OR

 

REPLACE

THE

 

FUSE

 

WITHOUT

 

HAVING

 

THE

 

PROBLEM

 

CORRECTED

,

YOU

 

RUN

 

THE

 

RISK

 

OF

 

SEVERE

 

EQUIPMENT

 

DAMAGE

.

B

EFORE

 C

ALLING

 Y

OUR

 S

ERVICER

Check the electrical panel  for tripped circuit breakers
or failed fuses. Reset the circuit breakers or replace fuses
as necessary.

Check the disconnect switch near the indoor furnace or
blower to confirm that it is closed.

Check for obstructions on the outdoor unit . Confirm that
it has not been covered on the sides or the top. Remove
any obstruction that can be safely  removed. If  the unit
is covered with dirt or debris, call a qualified servicer to
clean it.

Check for blockage of the indoor air inlets and outlets.
Confirm that they are open and have not been blocked
by objects (rugs, curtains or furniture).

Check the filter. If it is dirty, clean or replace it.

Listen for any unusual noise(s), other than normal
operating noise, that might be coming from the outdoor
unit.   If you hear unusual noise(s) coming from the unit,
call a qualified servicer.

SPLIT SYSTEMS

AIR CONDITIONING AND HEAT PUMP HOMEOWNER’S

 

ROUTINE MAINTENANCE RECOMMENDATIONS

We strongly recommend a bi-annual maintenance checkup be performed

before the heating and cooling seasons begin by a qualified servicer.

Содержание CONDENSING UNITAIR CONDITIONING

Страница 1: ...four and a minimum of two IMPORTANT SAFETY INSTRUCTIONS The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards It is the owner s and instal...

Страница 2: ...pads or springs can be installed between the con densing unit legs or frame and the roof mounting assembly to reduce noise vibration SAFE REFRIGERANT HANDLING While these items will not cover every co...

Страница 3: ...red Insulation must be installed in a manner which protects tubing from damage and contamination Where possible drain as much residual compressor oil from existing systems lines and traps pay close at...

Страница 4: ...ITROGEN CYLINDER MUST INCLUDE A PRESSURE REGULATOR AND A PRESSURE RELIEF VALVE THE PRESSURE RELIEF VALVE MUST BE SET TO OPEN AT NO MORE THAN 150 PSIG WARNING Pressure test the system using dry nitroge...

Страница 5: ...protection devices are approved for use Time delay fuses HACR type circuit breakers These devices have sufficient time delay to permit the motor compressor to start and accelerate its load HIGH VOLTA...

Страница 6: ...charge has bled into the system open the liquid service valve The service valve cap is the secondary seal for the valves and must be properly tightened to prevent leaks Make sure cap is clean and appl...

Страница 7: ...and superheat are high adjust TXV valve to 7 to 9 F superheat then check subcooling d If subcooling is high and superheat is low adjust TXV valve to 7 to 9 F superheat and remove charge to lower the...

Страница 8: ...another In a traditional system the thermostat sends commands to the indoor and outdoor units via analog 24 VAC signals It is a one way communication path in that the indoor and outdoor units typical...

Страница 9: ...mostat CT Compatible Air Handler Furnace Modular Blower Integrated Control Module CT Compatible AC HP Integrated Control Module 1 2 R C System Wiring Using Four Wires TWO WIRE OUTDOOR FOUR WIRE INDOOR...

Страница 10: ...displayed in the scrolling display area while the data is being retrieved The first sub menu is then displayed See tables below for listing of air conditioner submenus Touch the or _ to step through t...

Страница 11: ...ecent AC HP fault For display only Fault 6 FAULT 6 Least recent AC HP fault For display only Clear Fault History CLEAR NO or YES Selecting YES clears the fault history NOTE Consecutively repeated faul...

Страница 12: ...bmenu Item Indication for Display Only not User Modifiable Mode MODE Displays the current air conditioner or heat pump operating mode CFM CFM Displays the airflow for the current operating mode STATUS...

Страница 13: ...s dc Data 2 should be approximately 2 2 volts dc The voltage difference between data 1 and data 2 should be approximately 0 6 volts dc Verify that the bus TERM dipswitches are in the ON position 1 2 O...

Страница 14: ...are securely twisted together prior to inserting into terminal block Verify installation type legacy traditional or communicating Check data 1 data 2 voltages Rapid Flashing Normal network traffic Co...

Страница 15: ...rcuit Test Control Circuit with Voltmeter Low Voltage Test Voltage Faulty Evaporator Fan Motor Repair or Replace Shorted or Grounded Fan Motor Test Motor Windings Improper Cooling Anticipator Check Re...

Страница 16: ...e indicated code 6 Flashes ON OFF OFF x Board miss operation INTERNAL FAULT EE x Compressor relay contacts welded x Replace control x Turn power OFF prior to repair x Replace with correct replacement...

Страница 17: ...emory card x Error code will be cleared once data is loaded Applies only to fully communicating system using ComfortNet thermostat x Air conditioner heat pump fails to operate x Air conditioner heat p...

Страница 18: ...indoor blower motor repair replace as needed x Check indoor thermostat setting x Turn power OFF prior to repair x Fault will clear after 30 consecutive normal cycles x Fault may be cleared by cycling...

Страница 19: ...tdoor fan motor capacitor replace as needed x Turn power OFF prior to repair x Replace with correct replacement part s x Compressor and outdoor fan are off x Low pressure switch trip 3 times within sa...

Страница 20: ...ompressor repair replace as needed x Check compressor wiring repair replace as needed x Turn power OFF prior to repair x Fault will clear after 1 normal cycle x Fault may be cleared by cycling 24VAC t...

Страница 21: ...all x Open Run Circuit Lockout OPEN RUN LOCK 07 x Compressor run winding is open x Compressor not properly wired to control x Faulty compressor wiring x Check compressor repair replace as needed x Che...

Страница 22: ...Check transformer replace if needed x Turn power OFF prior to repair x Fault will clear if secondary voltage rises above 21VAC x Replace with correct replacement part s x Compressor is off x Integrat...