70
High pressure is measured at the suction service valve ( the larger valve).
AMPS = Outdoor unit amps (comp.+fan)
Low pressure is measured at the gauge port connection.
KW = Total system power
Calculations are based on nominal CFM and 70 °F indoor dry bulb.
HEATING PERFORMANCE DATA
EXPANDED PERFORMANCE DATA
MODEL: GSH13048-4A* / ARUF61-00*-1* / ARUF48601A*
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
54.1
51.2
48.2
45.0
43.0
41.7
38.7
35.7
43.6
40.3
37.1
35.0
33.7
30.2
26.8
23.4
20.0
16.3
Delta T
31.3
29.6
27.9
26.1
24.9
24.1
22.4
20.7
25.2
23.3
21.4
20.3
19.5
17.5
15.5
13.5
11.5
9.5
KW
3.87
3.78
3.70
3.61
3.56
3.52
3.44
3.36
3.29
3.20
3.12
3.07
3.03
2.95
2.86
2.78
2.69
2.61
AMPS
3.7
3.5
3.3
3.1
3.0
3.0
2.8
2.7
2.6
2.5
2.4
2.3
2.3
2.2
2.1
2.0
1.9
1.7
COP
4.09
3.96
3.81
3.65
3.53
3.46
3.29
3.11
3.88
3.68
3.48
3.34
3.25
3.00
2.74
2.46
2.17
1.84
EER
14.0
13.5
13.0
12.5
12.1
11.8
11.2
10.6
13.3
12.6
11.9
11.4
11.1
10.3
9.4
8.4
7.4
6.3
HI PR
180
172
166
158
155
152
146
140
134
128
123
120
118
113
109
105
101
97
LO PR
74
68
64
59
56
53
49
44
39
35
31
29
28
23
20
17
15
12
*Note: Shaded area is AHRI Rating Conditions at 47° outdoor ambient temperature.
EXPANDED PERFORMANCE DATA
MODEL: GSH130483A* / ARUF61-00*-1* / ARUF48601A*
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
54.1
51.2
48.2
45.0
43.0
41.7
38.7
35.7
33.6
31.1
28.6
27.0
26.0
23.3
20.7
18.0
15.4
12.6
Delta T
31.3
29.6
27.9
26.1
24.9
24.1
22.4
20.7
19.5
18.0
16.5
15.6
15.0
13.5
12.0
10.4
8.9
7.3
KW
3.71
3.64
3.57
3.50
3.45
3.42
3.35
3.28
3.34
3.26
3.19
3.14
3.11
3.04
2.96
2.89
2.81
2.74
AMPS
14.6
13.6
12.7
12.0
11.6
11.3
10.7
10.2
9.8
9.3
8.9
8.7
8.6
8.2
7.7
7.2
6.7
6.1
COP
4.26
4.11
3.95
3.77
3.64
3.56
3.38
3.18
2.95
2.79
2.63
2.51
2.44
2.25
2.04
1.83
1.60
1.35
EER
14.6
14.1
13.5
12.9
12.4
12.2
11.5
10.9
10.1
9.5
9.0
8.6
8.4
7.7
7.0
6.2
5.5
4.6
HI PR
224
215
206
197
193
189
182
174
167
159
153
149
147
141
136
130
126
121
LO PR
73
68
64
58
55
53
49
44
39
35
31
29
28
23
20
17
15
12
High pressure is measured at the suction service valve ( the larger valve).
AMPS = Outdoor unit amps (comp.+fan)
Low pressure is measured at the gauge port connection.
KW = Total system power
Calculations are based on nominal CFM and 70 °F indoor dry bulb.
*Note: Shaded area is AHRI Rating Conditions at 47° outdoor ambient temperature.
GSH13
Содержание ASH Series
Страница 76: ...5 W D H PRODUCT DIMENSIONS Model Dimensions W x D x H GSH101203AC 35 x 35 x 41 ...
Страница 210: ...CONTROL COVER CONTROL BOX 4 RP 364A www goodmanmfg com www amana hac com ...
Страница 212: ...COMPRESSOR TUBING ASSEMBLY 6 RP 364A www goodmanmfg com www amana hac com ...
Страница 214: ...COIL CABINET TOP SIDE PANELS 8 RP 364A www goodmanmfg com www amana hac com ...
Страница 219: ...Control Cover Control Box 4 RP 436G www goodmanmfg com www amana hac com ...
Страница 221: ...Basepan Compressor Coil Assembly 6 RP 436G www goodmanmfg com www amana hac com ...
Страница 223: ...Tubing Assembly 8 RP 436G www goodmanmfg com www amana hac com ...
Страница 225: ...Cabinet Top Side Panels 10 RP 436G www goodmanmfg com www amana hac com ...
Страница 230: ...Control Cover Control Box 4 RP 356D ...
Страница 232: ...Tubing Assembly 6 RP 356D ...
Страница 234: ...Cabinet Top Side Panels Cond Coil 8 RP 356D ...
Страница 239: ...Control Cover Control Box 4 RP 392E www amana hac com ...
Страница 241: ...Coil Compressor Tubing 6 RP 392E www amana hac com ...
Страница 243: ...Cabinet Top Side Panels 8 RP 392E www amana hac com ...
Страница 248: ...Control Cover Control Box 4 RP 569A www goodmanmfg com www amana hac com ...
Страница 250: ...Cabinet Top Side Panels Cond Coil 6 RP 569A www goodmanmfg com www amana hac com ...
Страница 252: ...Tubing Assembly 8 RP 569A www goodmanmfg com www amana hac com ...