Operating Your Dehumidifier
TANK FULL INDICATOR
When the water container is full, an alarm signal will be produced.
The compressor will stop automatically. This will also stop the dehumidification
process.
Empty the water container and replace it in the correct position, the dehumidifier will
continue dehumidifying when the compressor, restarts after three minutes.
PERMANENT WATER DRAINAGE
It is possible to connect a drainage tube with an inner diameter of 10mm (not
supplied) to the appliance for permanent water drainage.
If this option is desired, you will need to purchase a suitable PVC tube from your local
hardware retailer (Goldair does not hold tubes as spare parts).
Connect the drainage hose to the drain spout.
Place the end of the drainage hose in a drainage outlet. Ensure that the end of the
hose is lower than the drain opening, otherwise the water will not drain and flooding
may occur.
Also ensure the water tank is positioned in the unit otherwise the continuous
drainage will not operate. It will also catch any overflow.
When you no longer wish to use the permanent water drainage, disconnect the
drainage tube from the device and water will be collected in tank again.
DEFROSTING
When the machine is in an environment of low temperature during operation, the
surface of the evaporator may frost up. In order to ensure the normal operation of
the machine, it will go into an automatic defrosting function.