background image

The appliance must not be immersed in any liquids.

There are no user serviceable parts installed in the unit.

Do not place the unit in wardrobes or other enclosed spaces as this may cause
fire hazards.

This unit is not supposed to be used in or around locations where foodstuffs,
works of art or delicate articles of science, etc. are stored.

If your appliance does not work, or is not working properly, contact the place of
purchase or the Customer Services Team.

General Care and Safety Guide

Any repairs required, contact the nearest authorised Service 

Centre and strictly follow the manufacturer’s instruction only.

Appliance is filled with flammable gas R290.

Before using the appliance, read the manual.

Before installing the appliance, read the installation manual.

Caution, risk of fire

WARNING: 

Appliance shall be installed, operated and stored in a room 

with a floor area larger than 4m

2

.

Do not use any means to accelerate the defrosting process or to clean ,other than those 
recommended by the manufacturer.

The appliance shall be stored in a room without continuously operating ignition sources. 
(example: open flames, an operating gas appliance or an operating electric heater).

Do not pierce or burn.

Be aware that refrigerants do not have any odour.

Содержание GSD195

Страница 1: ...Operating Instructions Dehumidifier 10L Model GSD195 ...

Страница 2: ...This page is intentionally left blank ...

Страница 3: ... the unit WARNING Do not use this appliance in small rooms when they are occupied by persons not capable of leaving the room on their own unless constant supervision is provided WARNING To reduce the risk of fire keep textiles curtains or any flammable material a minimum distance of 1 metre from the air outlet General Care and Safety Guide Use only the voltage specified on the rating label of the ...

Страница 4: ...e area and is unrolled before use It is recommended that this appliance is plugged directly into the wall socket Power boards are not rated to supply power to high wattage appliances A correctly specified undamaged extension cord may be used with this appliance provided it is used in a safe manner Do not remove plug from power socket until the appliance has been switched off Do not remove plug fro...

Страница 5: ...e nearest authorised Service Centre and strictly follow the manufacturer s instruction only Appliance is filled with flammable gas R290 Before using the appliance read the manual Before installing the appliance read the installation manual Caution risk of fire WARNING Appliance shall be installed operated and stored in a room with a floor area larger than 4m2 Do not use any means to accelerate the...

Страница 6: ...ered or positioned incorrectly WARNING Never leave this dehumidifier unattended Ensure dehumidifier is on a flat stable heat resistant surface Once the dehumidifier is in a safe operating position and all switches are in the off position insert the power plug into the mains outlet and switch on CAUTION Ensure the power cord is not tight because if pulled it may partially pull the plug from the soc...

Страница 7: ...r 3 When the humidity drops to the set humidity the machine will stop automatically E g In the dehumidification operation Set the humidity level to 40 When the appliance detects that the current environment humidity is higher than or equal to 42 RH the dehumidifier will start to dehumidify When the appliance detects that the current environment humidity is less than or equal to 38 RH the dehumidif...

Страница 8: ...ocal hardware retailer Goldair does not hold tubes as spare parts Connect the drainage hose to the drain spout Place the end of the drainage hose in a drainage outlet Ensure that the end of the hose is lower than the drain opening otherwise the water will not drain and flooding may occur Also ensure the water tank is positioned in the unit otherwise the continuous drainage will not operate It will...

Страница 9: ...umidifier has been allowed to cool down completely before cleaning The common cause of overheating is deposits of dust or fluff in the appliance Ensure these deposits are removed regularly by unplugging the appliance and vacuum cleaning the air vents and grills Use a damp cloth not wet to wipe the exterior of the dehumidifier to remove dust and dirt Never use solutions such as petrol thinners or p...

Страница 10: ...r filter is clogged Clean the air filter The temperature or relative humidity in the room where the device is operating is too low It is normal that the device does not dehumidify in these conditions The dehumidifier works but reduces the relative humidity insufficiently The room is too large We recommend using a dehumidifier with a greater capacity There are too many sources of humidity We recomm...

Страница 11: ...under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure In New Zealand this warranty is additional to the conditions and guarantees...

Страница 12: ...New Zealand PO Box 100707 North Shore Mail Centre Auckland 0745 www goldair co nz Australia PO Box 574 South Morang Victoria 3752 www goldair com au ...

Отзывы: