Macho Pop
Model No. 2553 Series and 2554 Series
Page 7
gmpopcorn.com
OPERATING INSTRUCTIONS
Controls and Their Functions
LIGHTS/WARMER SWITCH
Two position (ON/OFF), lighted rocker switch(s) which operates the interior light, dome
light, and heat element for the corn deck freshener.
KETTLE MOTOR SWITCH
Two position (ON/OFF), lighted rocker switch which operates the kettle agitator motor,
and the exhaust fan. The Kettle Motor Switch MUST be ON at all times when there is
popcorn (popped or un-popped) in the kettle. When finished popping, the unit should be
sufficiently vented before turning off the exhaust fan.
KETTLE HEAT SWITCH
Two position (ON/OFF), lighted rocker switch which operates the heating element in the
popping kettle, by s
ending power to the “Big Eye”
electronic temperature control system.
LIGHT & AUDIBLE LOAD DUMP SIGNAL
Yellow indicator light and audible sound (if engaged), used to signal Load Dump.
Therefore, if the yellow light is ON, and the buzzer is sounding,
one
of the following
actions should be taken:
•
Load the corn and oil
or
•
Dump the popped corn from the kettle
or
•
Turn OFF the Kettle Heat Switch if you are finished popping corn.
Note:
This light is also used to indicate Auto Shut Off (if enabled) and Control Board error
codes (reference the Temperature Control Board section of this manual).
SALT/SWEET SWITCH (if equipped)
Two position covered rocker switch used to adjust the kettle temperature for Salt or
Sweet popping mode.
OIL DISPENCE PUSH BUTTON SWITCH & GREEN OIL LIGHT (if equipped)
“Red” Oil Dispense P
ush Button (PB) Switch which dispenses a predetermined amount of oil
into the kettle when pressed. The Oil System Master Switch must be in the ON position for the
Oil Dispense PB Switch to activate (reference the Instruction Manual for the oil dispense
unit). The Green Oil Light on the popper will only light up when the oil pump is dispensing.
OIL SYSTEM MASTER SWITCH (if equipped)
Two position, ON/OFF lighted rocker switch - supplies power to the oil pump (either the
Bag-in-a-Box or Bucket Pump model). Reference the Instruction Manual for the oil
dispense unit.
Bag-in-a-Box Model
: Oil System Master Switch ON, provides power to the oil dispense
unit, activates the warmer/blower, and the heated line kit (if equipped).
Note:
Coconut oil will congeal at temperatures below approximately 76°F (24°C). For
machines used daily, leave the Oil System Master Switch on at all times and keep
Содержание Macho Pop 2553 Series
Страница 40: ...Macho Pop Model No 2553 Series and 2554 Series Page 40 gmpopcorn com Front Counter Model Series 2554 ...
Страница 41: ...Macho Pop Model No 2553 Series and 2554 Series Page 41 gmpopcorn com Back Counter Model Series 2553BC ...
Страница 42: ...Macho Pop Model No 2553 Series and 2554 Series Page 42 gmpopcorn com Back Counter Model Series 2554BC ...